Function Description - Elitech STC-1000Pro TH Quick Start Manual

Intelligent temperature and humidity controller
Table of Contents

Advertisement

4. Function Description

4.1 Temperature Setting - TCH, TS, TD
Cooling mode (TCH = C)
When T
(temperature-present value) is higher than TS + TD
PV
(temperature-set value + temperature di erential),
work1 will be turned on, and cooling will begin;
When T
(temperature-present
PV
value) is lower than TS (temperature
-set value),
will be turned o , and cooling will
stop.
For example: TS = 15°C, TD = 5°C, as
shown in Fig. 8.
Heating mode (TCH = H)
When T
(temperature-present value) is lower than TS - TD (tempera-
PV
ture-set value - temperature di erential),
turned on, and heating will begin;
When T
(temperature - present
PV
value) is higher than TS (temperature
-set value),
will be turned o , and heating will
stop.
For example: TS = 15°C, TD = 5°C, as
shown in Fig. 9.
4.2 Temperature Protection Time - TPT
WORK1 is a temperature socket and the time interval from its power-o
to power-on again should meet the time requirement for TPT. If not,
will flash.
This protection time requirement should also be satisfied when the
controller is just powered on.
will disappear, work1
will disappear, work1
°C
20
TS=15
will appear, work1 will be
°C
TS=15
10
-9-
will appear,
WORK1 On
WORK1 O
TD=5
Fig. 8
WORK1 On
WORK1 O
TD=5
Fig. 9
t
t
or

Hide quick links: