Advanced Charge Algorithm
precharge function by requesting 0 mA charging current from the charger. The [PCHG] = 1. CHG FET is used in
PRECHARGE mode.
The device also supports 0-V charging. It enables the hardware 0-V charging circuit automatically when the
battery stack voltage is below the minimum operation voltage of the device. See the BQ28Z610 1-Cell to
2-Series Cell Li-Ion Battery Pack Manager Data Sheet (SLUSAS3) for BQ28Z610-R2 electrical specifications.

4.10 Maintenance Charge

Maintenance charge [MCHG] can allow charge after termination has been reached. This is only possible if
the GaugingStatus()[TC] flag is not set. This means to use maintenance charge. [TCSETSOC] should not be
enabled, and instead [TCSETV] can be used to stop maintenance charge based on voltage. Also, [CHGFET]
should be disabled so that, on detection of a valid primary termination, the charge FET does not open.
Status
Condition
ChargingStatus()[IN] = 0 AND ChargingStatus()
Set
[SU] = 0 AND ChargingStatus()[PV] = 0 AND
GaugingStatus()[TCA] = 1
ChargingStatus()[IN] = 1 OR
ChargingStatus()[SU] = 1 OR
Clear
ChargingStatus()[PV] = 1 OR
GaugingStatus()[TCA] = 0

4.11 BROADCAST Mode

BROADCAST mode is available in the latest firmware version in the BQ28Z610-R2 product folder on
TI.com. BROADCAST mode is not included in the shipped version.
The BQ28Z610-R2 gauge enables a smart battery to become the I
and current to a smart battery charger. This allows the charger and gauge to operate autonomously to adjust
the charging conditions dynamically without requiring the host or system to be booted or active. For more
information, see Charger.
The [BCAST] bit enables all broadcasts to a host or a smart charger. When the [BCAST] bit is enabled, the
following broadcasts are sent:
ChargingVoltage() and ChargingCurrent() broadcasts are sent to the smart-charger Device Address, and the
broadcast period is set in Broadcast Pacing. The target registers accessed for writing ChargingVoltage()
and ChargingCurrent() values to the charger device are configured in the data flash registerVoltage Register
and the data flash register Current Register, respectively.

4.12 Charge Disable and Discharge Disable

The BQ28Z610-R2 device can disable charging if certain safety conditions are detected, setting the
OperationStatus()[XCHG] = 0.
Status
Condition
SafetyStatus()[COV] = 0 AND
SafetyStatus()[OCC] = 0,0 AND SafetyStatus()[ASCC] = 0 AND
Normal
AND SafetyStatus()[CTO] = 0 AND
SafetyStatus()[PTO] = 0 AND
GaugingStatus()[TCA] = 0 if Charging Configuration[CHGFET] = 1
28
BQ28Z610-R2
Action
ChargingStatus()[MCHG] = 1
ChargingVoltage() = Charging Algorithm
ChargingCurrent() = Charging Algorithm
ChargingStatus()[MCHG] = 0
ChargingVoltage() = Charging Algorithm
ChargingCurrent() = Charging Algorithm
Note
Copyright © 2022 Texas Instruments Incorporated
2
C master to broadcast the charging voltage
Action
ChargingVoltage() = Charging Algorithm
ChargingCurrent() = Charging Algorithm
OperationStatus()[XCHG] = 0
www.ti.com