8) Remove the closed end connectors from the Pump Motor leads.
9) Remove the two screws and the Pump Motor Bracket.
10) Remove the Pump Housing, and check the Impeller.
11) If the Impeller is defective, install a new Impeller.
12) Install the new motor or new parts, and replace the removed parts in the reverse
order of which they were removed.
13) Turn on the power supply, and check for leaks.
14) Replace the Base Cover in its correct position.
15) Replace the Front Panel in its correct position.

14. REMOVAL AND REPLACEMENT OF SPRAY TUBE

1) Turn off the power supply.
2) Remove the Front Panel and the Insulation Panel.
3) Remove the Rubber Hose from the Spray Tube (Water Supply Pipe).
4) Release the Clamp, and disconnect the Rubber Hose.
5) Remove the Spray Tube by squeezing the side tab.
6) Install the new Spray Tube, and replace the removed parts in the reverse order of
which they were removed.
7) Replace the panels in their correct positions.
8) Turn on the power supply.