Electrical Connection; Stacking Remote Condenser Unit - Hoshizaki KM-1601SRH Instruction Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1601SRH:
Table of Contents

Advertisement

5. Electrical Connection

1. Electrical connections must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could cause severe
injury to individuals or extensive damage to equipment.
. Be sure to install a proper ground from the icemaker to the remote condenser
unit.
• This remote condenser unit must be connected to the fan motor junction box on the
icemaker.
• The opening for the power supply connection is 7/8" DIA to fit a 1/" trade size conduit.
• Usually an electrical permit and services of a licensed electrician are required.
1) Remove the louver panel. See Fig. 13.
) Remove the junction box cover on the remote condenser unit. Remove the fan motor
junction box cover on the icemaker.
3) Install a ground wire from the icemaker to the remote condenser unit.
4) Connect the fan motor leads in the junction box of the remote condenser unit to the fan
motor leads in the fan motor junction box of the icemaker.
5) Replace the junction box covers and the louver panel in their correct positions.

6. Stacking Remote Condenser Unit

1) Install the lower remote condenser unit as described earlier in this section.
) Place the upper remote condenser unit on top of the lower. See Fig. 14.
3) Secure the upper remote condenser unit with the four screws provided.
4) Install refrigerant lines, and make electrical connections for each fan motor as described
earlier in this section.
Screws
Louver Panel
Fig. 13
WARNING
Screws
Junction Box Cover
Fig. 14
19
Upper
Condenser
Unit
Screws
Lower
Condenser
Unit