F. Electrical Connection
1. Electrical connection must be made in accordance with the instructions on
the "WARNING" tag, provided with the pig tail leads in the junction box.
. Electrical connections must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could cause severe
injury to individuals or extensive damage to equipment.
3. Be sure to install a proper ground to the icemaker.
• Electrical connections must be installed in accordance with applicable national, state,
and local regulations.
• The icemaker requires an independent power supply. See the nameplate for proper
voltage and breaker/fuse size.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• On single phase models only, the white lead must be connected to the neutral
conductor of the power source. Miswiring results in severe damage to the icemaker.
See Fig. 8.
• On three phase models, the transformer's voltage tap switch should be positioned to
match incoming voltage at startup. See Fig. 9.
• The opening for the power supply connection is 7/8" DIA to fit a 1/" trade size conduit.
• Usually an electrical permit and services of a licensed electrician are required.