Scaling Screen
This screen is only accessible when logged in as
one of the "Maintenance" usernames.
JJ
JL
JH
F
. 15: This screen is for qualified technicians only and is password protected.
IG
Key:
JA Current K Factor Value
JB Test Shot Actual Weight (grams)
JC Iso Calibration Shot start button
JD Poly Calibration Shot start button
JE Calibration Shot stop button
JF Temperature Log screen access
See Calibrating Machine-Calculated Mass Flow on
page 50 for more information.
Flowrate Filter
The flowrate input and display may be filtered to provide
a more stable display of flow rate by turning the filter
ON. Instantaneous flow rate changes are displayed with
the filter turned off.
313813A
JA
JK
JG Flowrate Filter On/Off
JH Last Shot Data
JJ Calculate New K Factor button
JK Flow Meter Reading (grams per second)
JL Test Flowrate (grams per second)
JB
JC
JD
JE
JG
JF
Operation
29