WorldDSL
WorldDSL
Q
I
G
UICK
NSTALLATION
UIDE
UTU-702C List 1
Rate Selectable Line Unit
Part Number: 150-1422-02C
ETU-752C List 1
Rate Selectable Desktop Unit
Part Number: 150-1432-02C
W
o r
l d D
S L
G . 7
0 3
H D
S L

Advertisement

Table of Contents
loading

Summary of Contents for ADC WorldDSL UTU-702C

  • Page 1 WorldDSL WorldDSL UICK NSTALLATION UIDE UTU-702C List 1 Rate Selectable Line Unit Part Number: 150-1422-02C ETU-752C List 1 Rate Selectable Desktop Unit Part Number: 150-1432-02C l d D G . 7...
  • Page 2 In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
  • Page 3 Unpack each container and inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC DSL Systems, Inc. Order replacement equipment, if necessary.
  • Page 4 Unpack and Inspect Your Shipment 700-702-900-04, Revision 04 June 14, 2002 UTU-702C and ETU-752C List 1...
  • Page 5: Table Of Contents

    700-702-900-04, Revision 04 Table of Contents ABLE OF ONTENTS Overview _______________________________________________ 1 Rate Selectable HDSL ............. 1 UTU-702C Line Unit ............... 1 ETU-752C Desktop Unit ............2 Interoperability................. 2 Transmission Ranges ............... 2 Compatibility ................3 Shelves and Enclosures for UTU-702C ....3 Connector Adapters for ETU-752C......
  • Page 6 List of Figures 700-702-900-04, Revision 04 Monitor LTU and NTU Interface Screens ....19 Monitor HDSL Span Screen ........20 Product Support_________________________________________21 Certification and Warranty _________________ Inside Back Cover IST OF IGURES UTU-702C Front Panel................4 UTU-752C Front Panel................4 ETU-752C Rear Panel ................7 UTU/ETU Console Port and Maintenance Terminal Connector Pinouts................13 IST OF...
  • Page 7: Overview

    700-702-900-04, Revision 04 Overview VERVIEW ™ This guide contains installation information for the ADC WorldDSL UTU-702C List 1 and ETU-752C List 1 Rate Selectable (RS) line and desktop units. HDSL ELECTABLE WorldDSL RS is a single pair High-bit-rate Digital Subscriber Line (HDSL) solution that offers extended reach capabilities through the use of industry-leading multi-rate DSL technology.
  • Page 8: Etu-752C Desktop Unit

    Overview 700-702-900-04, Revision 04 ETU-752C D ESKTOP The ETU-752C is housed in a plastic enclosure with interface and power connectors for use as an integrated desktop unit. All functions of the ETU-752C, with exception of power requirements, are identical to the UTU-702C.
  • Page 9: Compatibility

    700-702-900-04, Revision 04 Overview OMPATIBILITY The UTU-702C and ETU-752C are compatible with the following ADC WorldDSL products. Shelves and Enclosures for UTU-702C • EMS-830 Exchange Office Management Shelf, rear connector access (part number 150-1400-01). • EMS-831 Exchange Office Management Shelf, front connector access (part number 150-1401-01).
  • Page 10: Front Panels

    Overview 700-702-900-04, Revision 04 RONT ANELS The components on the UTU-702C and ETU-752C front panels are shown below. Their functions are described on page 5 page HDSL LEDs I/F ALM LED Loopback LEDs and push buttons Bar code label (located on circuit side of line card) V.24 (RS-232) console port Warranty control...
  • Page 11: Utu And Etu Front Panel Components

    700-702-900-04, Revision 04 Overview UTU and ETU Front Panel Components Item Function HDSL SYNC LED Displays synchronization state for the HDSL loop. HDSL ALM LED Displays alarm state for the HDSL loop. I/F ALM LED Displays the Nx64k interface (I/F) alarm state. LOC LPBK LED Displays local (LOC) loopback state.
  • Page 12: Utu And Etu Front Panel Led Indications

    For information on loopback testing and loopback LED indications, see the WorldDSL RS Rate Selectable HDSL Line and Desktop Units user manual, section 700-702-100-xx. This document can be downloaded from the ADC website at www.adc.com. June 14, 2002 UTU-702C and ETU-752C List 1...
  • Page 13: Etu-752C Rear Panel

    700-702-900-04, Revision 04 Overview ETU-752C R ANEL The components on the ETU-752C rear panel are shown and described below. ETU-752C Rear Panel ETU-752C Rear Panel Components Item Description D25F data port connector Connects Nx64k data circuits to the enclosure. D9F HDSL line connector Connects the HDSL pairs to the enclosure.
  • Page 14: Installation

    Before installing the line or desktop unit, inspect it for signs of damage. If the unit has been damaged in transit, immediately report the extent of the damage to the transportation company and to ADC DSL Systems, Inc. AFETY To ensure your safety when servicing and installing this equipment, please take the following precautions: Be careful when installing or modifying telephone lines.
  • Page 15: Line Unit Installation

    700-702-900-04, Revision 04 Installation NSTALLATION To install the UTU-702C line unit into a shelf or remote enclosure: The chassis ground of the shelf or remote enclosure receiving these units must be connected to earth ground for protection of the equipment and for safety of personnel. Other protection is required when the network side of the equipment is extended to an outside facility.
  • Page 16 Installation 700-702-900-04, Revision 04 Connect the data port cable from the DTE to the data port connector on the ETU-752C rear panel. Connect the HDSL line cable to the HDSL line connector on the ETU rear panel. The pinouts for the HDSL line connector are listed in the following table.
  • Page 17: Hdsl Startup And Synchronization

    700-702-900-04, Revision 04 Installation HDSL S TARTUP AND YNCHRONIZATION At startup, a WorldDSL RS LTU confirms that it is communicating with a WorldDSL RS NTU. The LTU then synchronizes the NTU configuration with its own configuration. Power up the LTU and NTU. The following synchronization sequence should occur: Power up the shelf or enclosure where the unit(s) are installed.
  • Page 18: System Configuration

    System Configuration 700-702-900-04, Revision 04 YSTEM ONFIGURATION After synchronization is established, the HDSL system can be configured and performance can be monitored from the local unit. If the HDSL link is down, the only parameters that can be changed are those on the local unit. The LTU also provides a special lockout feature that prevents users plugged into the NTU console port from changing the circuit configuration.
  • Page 19: Logging On

    700-702-900-04, Revision 04 System Configuration UTU/ETU Console Port and Maintenance Terminal Connector Pinouts OGGING To log on to the maintenance terminal console screen: Press the SPACEBAR several times to activate the autobaud feature and to display the Logon Password screen. ENTER key is the factory default password.
  • Page 20: Navigating Menus

    System Configuration 700-702-900-04, Revision 04 AVIGATING ENUS Use the keys described in the following table to navigate the console screen and its menus. Console Screen Navigation Keys These Keys Perform this Function Alpha-numeric Type the underlined or highlighted letter to select and execute a menu keys item.
  • Page 21: System Settings

    700-702-900-04, Revision 04 System Configuration YSTEM ETTINGS The following table lists the settings available in the Config System Settings menu. The settings in boldface type are factory default settings. Settings in Config System Settings Menu Settings Description Application Mode SINGLE System uses a single pair of twisted copper wire to transport data.
  • Page 22: Ltu And Ntu Interface Settings

    System Configuration 700-702-900-04, Revision 04 NTU I NTERFACE ETTINGS The following table lists the settings available in the Config LTU and Config NTU Interface menus. The settings in boldface type are factory default settings. Settings in Config LTU and Config NTU Interface Menus Settings Description Primary Timing...
  • Page 23: Viewing Status

    700-702-900-04, Revision 04 Viewing Status IEWING TATUS View status using a maintenance terminal or PC running a terminal emulation program connected to the unit’s V.24 (RS-232) console port. ONSOLE CREEN The main console screen displays a summary of LTU and NTU circuit configuration, as well as performance statistics and alarm status for each interface.
  • Page 24 Viewing Status 700-702-900-04, Revision 04 Information Displayed in Main Console Screen (Cont.) Field Description Displays the ES counts for each HDSL interface. The counts are for the latest 24-hour period, calculated as the sum of the counts in the previous 95 15-minute intervals, plus the count in the current 15-minute interval.
  • Page 25: Monitor Screens

    700-702-900-04, Revision 04 Viewing Status ONITOR CREENS The Monitor screens display the signal activity at the LTU/NTU serial data port, and the 24-hour error counts and other information from the HDSL Span 1 interface. Monitor LTU and NTU Interface Screens The following table lists the information displayed in each field of the Monitor LTU and Monitor NTU Interface screens.
  • Page 26: Monitor Hdsl Span Screen

    Viewing Status 700-702-900-04, Revision 04 Monitor HDSL Span Screen The following table lists the information displayed in each field of the Monitor HDSL Span 1 screen. Information Displayed in Monitor HDSL Span 1 Screen Field Description Current Margin Indicates the excess signal-to-noise ratio relative to a 10 bit error (dB) (MAR) rate.
  • Page 27: Product Support

    ADC Customer Service Group provides expert pre-sales and post-sales support and training for all its products. Technical support is available 24 hours a day, 7 days a week by contacting the ADC Technical Assistance Center at the number listed below. • Quotation Proposals Sales Assistance •...
  • Page 28 Product Support 700-702-900-04, Revision 04 June 14, 2002 UTU-702C and ETU-752C List 1...
  • Page 29: Certification And Warranty

    60-month warranty period per ADC's instructions and which product is confirmed by ADC not to comply with the foregoing warranty. ADC warrants that, for a period of 90 days from the date of purchase, the software furnished with its products will operate substantially in accordance with the ADC published specifications and documentation for such software.