Ensure wood or timber floors are prop-
erly protected in order to prevent the
weight of the appliance from damag-
ing them during movement.
During lifting, avoid jerking or abrupt movements.
Pay attention to overbalancing.
5.2 checking the floor where the
appliance will be placed
Check the load capacity of the floor slab.
If a floor is not suitable for supporting the
weight of the appliance, install appropriate
steel plates (A - Fig. 7) or concrete base (A - Fig.
8)
equipped
with
mesh (b  -  Fig. 8) to distribute the weight.
For the dimensions of the plates and
the concrete base, use a qualified
technician.
It is advisable to install the appliance at a height
of approximately 35-40 cm from the floor to the
fire bed to facilitate its use.
To level the appliance, use the dedicated ad-
justment screws located under the feet of the
appliance.
A
Product images are for illustrative
purposes only
004778930 - 06/12/2021
ITALIANO
ENGLISH
10x10x6
electro-welded
10 mm
Fig. 7
DEUTSCH
FRANÇAIS
A
B
Product images are for illustrative
purposes only
6
PREPARInG THE PlAcE
oF InSTAllATIon
6.1

General considerations

The following sections contain some guidelines
to be followed to obtain the maximum efficiency
of the product purchased and to ensure safe
operation. The following indications are however
subject to compliance with any possible nation-
al, regional and municipal laws and regulations
in force in the country where the appliance is
installed.
In Italy, installation must be performed by quali-
fied personnel in compliance with the EN 10683
standard.

6.2 Safety Precautions

The operations for assembly and disassembly of
the appliance are reserved for specialist techni-
cians only.
It is recommended to be sure of their qualifica-
tions and their actual capacity.
For Italy, these technicians must be in
possession of the letter "C" qualifica-
tion issued by the chamber of com-
merce based on the Ministerial Decree.
37/08.