Display
dEF
Next display after these is the defrost initiation
temperature.
In1
(Refrigerator
Only)
13
Indicates that the setpoint for defrost initiation is 13°F.
dEF
Next display after these is the defrost termination temperature.
End
(Refrigerator
Only)
40
Indicates that the setpoint for defrost termination is 40°F.
dEF
Next display after these is the number of hours between defrosts.
Int
(Freezer Only)
4
Indicates that there will be one defrost every 4 hours.
WARNING: This value should be adjusted only after consulting with
the factory.
dEF
Next display after these is the maximum allowable time for a defrost.
The freezer's target is to terminate before this value is reached. This
dUr
value is a safety.
(Freezer Only)
60
Indicates that the maximum time for a defrost is 60 minutes.
WARNING: This value should never be changed from the default.
dEF
Next display after these is the defrost termination temperature. The
freezer's target is to terminate at this value.
HI
(Freezer Only)
100
Indicates that the defrost termination temperature is 100°F.
SHo
Next display after these is the short cycle timer. The short cycle time
is the minimum time the compressor must remain off in an off cycle
CyC
or on in an on cycle.

Indicates that the short cycle timer is set to .0 minutes.
FAn
Next display after these is the re-initiation temperature of the
evaporator fan after a defrost.
HI
(Freezer Only)
0
Indicates that the evaporator fan re-initiation temperature after a
defrost is 70°F.
COI
Next display after these is the defrost sensor temperature.
SEn
0
Indicates that the temperature of the defrost sensor is 0°F.
Indication
15
Default
Refrigerator
Freezer
13°F
NA
(7°F for
RH1-AAC-W)
40°F
NA
NA
Every 4
hours
NA
60 min.
NA
100°F
.0 min.
.0 min.
NA
70°F
NA
NA