Page 1
HOSHIZAKI EUROPE B.V. HOSHIZAKI SERVICE MANUAL PREMIER 70 / PREMIER W80 / PREMIER 60 As the user, please use the operating instructions. This service manual does not include operating instructions. It is only intended for the service technician. here.
HOSHIZAKI EUROPE B.V. Content 1) Safety Information ........................3 2) Intended Use ..........................3 3) Suitable Installation Site ......................3 4) Setting up Several Cabinets Side by Side ...................5 5) Unpacking and Installing the Cabinet ..................6 6) Condensation Water Re-evaporation ...................8 7) Electrical Connection........................9 8) Instructions for Daily Use ......................9...
HOSHIZAKI EUROPE B.V. 1) Safety Information This service manual does not include comprehensive operating instructions for the user; it is only a further supplement to the operating instructions. It intends for a trained service technician. As a result, many important safety instructions for the user are missing about the scope and readability.
Page 4
HOSHIZAKI EUROPE B.V. Distance from walls and ceiling: A gap of at least 500 mm must be kept between the top edge of the machine compartment and the ceiling, and of at least 50 mm from walls, furniture and other cabinets.
HOSHIZAKI EUROPE B.V. 4) Setting up Several Cabinets Side by Side Depending on the temperature and air humidity at the installation site as well as the selected set point setting, the moisture in the ambient air can condense on the surface of a refrigerating unit due to its design.
HOSHIZAKI EUROPE B.V. 5) Unpacking and Installing the Cabinet Warning The refrigeration unit is located at the top of the cabinet. At least two people are required to lay down the cabinet and set it up right again. Important If the cabinet has laid on its back or was transported horizontally, then it must stand upright for at least two hours before switching it on to allow the oil to collect in the compressor.
Page 7
HOSHIZAKI EUROPE B.V. 7-8- Then, 2 pieces of short wooden pieces at the back of the pallet are removed by hand. Once the pieces of wood that hold the cabinet to the pallet are removed, it means the cabinet is no longer connected to the pallet.
HOSHIZAKI EUROPE B.V. Cabinets on legs: Cabinets on legs require an even, solid floor. Cabinets on legs are levelled by turning the internal part of the feet. Cabinets on castors: Cabinets on castors require a level, even and solid floor to provide a stable foundation. After correctly positioning the cabinet, the two brakes on the front castors must be applied.
HOSHIZAKI EUROPE B.V. 7) Electrical Connection The 220-230 V/50 Hz mains connection is established by plugging the provided cable with appliance connector into a socket with earthed protective contact. 30 mA residual current circuit breaker is essential. There may be special regulations from your local energy supply company regarding earthing measures that must be observed.
HOSHIZAKI EUROPE B.V. 9) Cleaning and Maintenance The cabinet must be cleaned regularly. The intervals depend on the usage and level of soiling (at least annually). Before carrying out any cleaning or maintenance operations, unplug the unit Don’t touch or wet the machine compartment parts. This could result in failure or breakdown.
Page 11
HOSHIZAKI EUROPE B.V. Condenser Use vacuum cleaner or a soft brush to remove dust and stains from the condenser. Warning: If users clean the condenser with hard brush, such as dishwasher brush, the coating of condenser may peel off. *Air Filter To prevent deformation do not wash the air filter hot water above 40°...
HOSHIZAKI EUROPE B.V. 10) Control Elements Switching the device on and off If POF = 1 (default), touch the on/stand-by key for 2s the device is switched on, the display will show “P5” value (“cabinet temperature” default); if the display shows an alarm code, see the section ALARMS.
Page 13
HOSHIZAKI EUROPE B.V. If Loc = 1 (default) and 30 sec. have elapsed without the keys being pressed, the display will show the “Loc” label and the keypad will lock automatically. Unlock keypad Touch a key for 1 sec: the display will show the label “UnL”.
Page 14
HOSHIZAKI EUROPE B.V. Activate/deactivate energy saving in manual mode (if r5= 0) Check that the keypad is not locked. Touch the DEFROST key. The setpoint becomes “setpoint + r4” at maximum for HE2 duration. Activate the high or low humidity functions (if F0 = 5) Check that the keypad is not locked.
Page 15
HOSHIZAKI EUROPE B.V. Touch the SET key. Touch ON/STAND-BY exit procedure (or do not operate for 60 sec.). Example of alarm information (e.g. a high temperature alarm) critical value was 8.0 °C / °F (calculated cabinet/product temperature) available in EVJ213, EVJ214, EVJ214N7VXXRXV, EVJ215, EVJ234,...
Page 16
HOSHIZAKI EUROPE B.V. View the temperature detected by the probes. Check that the keypad is not locked. Touch the DOWN key for 1 sec. Touch the UP or DOWN key within 15 sec. to select a label. DESCRIPTION Cabinet temperature (if P4 = 0, 1 or 2)
Page 17
HOSHIZAKI EUROPE B.V. Set the date, time and day of the week (available in EVJ213, EVJ214, EVJ214N7VXXRXV, EVJ215, EVJ234, EVJ235 or in EVJ203, EVJ204, EVJ205, EVJ224 and EVJ225 with interface EVIF25TBX or EVIF25TWX connected) N.B. - If the device is connected to the interface EVIF25TBX, do not disconnect the device from the mains within two minutes since the setting of the time and day of the week.
Page 18
HOSHIZAKI EUROPE B.V. Reset the factory settings N.B. Check that the factory settings are appropriate; see the section CONFIGURATION PARAMETRES. Touch the SET key for 4 sec. The display will show the label “PA”. Touch the SET key. Touch the UP or DOWN key within 15 sec. to set “149”.
Page 19
HOSHIZAKI EUROPE B.V. ALARMS CODE DESCRIPTION RESET TO CORRECT Cabinet Probe Alarm automatic - check P0 Evaporator Probe Alarm automatic - check probe integrity - check electrical connection Auxiliary Probe Alarm automatic Clock Alarm manual Set date, time and day of the week.
Page 20
HOSHIZAKI EUROPE B.V. PARAMETER LIST PREMIER PREMIER PREMIER PREMIER K 70 KG 70 M 70 F 70 DESCRIPTION VALUE VALUE VALUE VALUE CODE Set point CA1 cabinet probe offset CA2 evaporator probe offset CA3 Auxillary probe offset probe type enable °C decimal point...
Page 21
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K 70 KG 70 M 70 F 70 DESCRIPTION VALUE VALUE VALUE VALUE CODE d3b defrost duration for B enable defrost at power-on defrost dealy after power-on value displayed during defrost dripping time...
Page 22
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K 70 KG 70 M 70 F 70 DESCRIPTION VALUE VALUE VALUE VALUE CODE evaporator fan on time during energy saving high/low humidity operation threshold for evaporator fan on after dripping (relative to setpoint)
Page 23
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K 60 KG 60 M 60 F 60 DESCRIPTION VALUE VALUE VALUE VALUE CODE Set point cabinet probe offset evaporator probe offset Auxillary probe offset probe type enable °C decimal point temperature unit of measurement...
Page 24
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K 60 KG 60 M 60 F 60 DESCRIPTION VALUE VALUE VALUE VALUE CODE enable defrost at power-on defrost dealy after power-on value displayed during defrost dripping time dripping time for B defrost interval counting mode...
Page 25
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K 60 KG 60 M 60 F 60 DESCRIPTION VALUE VALUE VALUE VALUE CODE evaporator fan on time during energy saving high/low humidity operation threshold for evaporator fan on after dripping (relative to setpoint)
Page 26
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K W80 KG W80 M W80 F W80 DESCRIPTION VALUE VALUE VALUE VALUE CODE Set point CA1 cabinet probe offset CA2 evaporator probe offset CA3 Auxillary probe offset probe type enable °C decimal point...
Page 27
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K W80 KG W80 M W80 F W80 DESCRIPTION VALUE VALUE VALUE VALUE CODE enable defrost at power-on defrost dealy after power-on value displayed during defrost dripping time d7b dripping time for B...
Page 28
HOSHIZAKI EUROPE B.V. PREMIER PREMIER PREMIER PREMIER K W80 KG W80 M W80 F W80 DESCRIPTION VALUE VALUE VALUE VALUE CODE high/low humidity operation threshold for evaporator fan on after dripping (relative to setpoint) threshold for evaporator fan operation differential...
HOSHIZAKI EUROPE B.V. 11) Switching the Door Hinge Side The door hinge side can be changed without additional parts. The hinge brackets are asymmetrical, so you must take special care to not get them mixed up – if in doubt, label them before making the modification.
Page 30
HOSHIZAKI EUROPE B.V. The following description applies to the modification from right to left. In the opposite situation, the corresponding procedure is reversed. 1. Remove the fastening screw 2. Fold the canopy upwards 3. Open the door at an angle...
Page 31
HOSHIZAKI EUROPE B.V. 7. Remove the door closer 8. Move the hinges from the 9. Remove the blind plugs for without turning the door closer bottom right to the top left, this. square. and from the top right to the bottom left;...
HOSHIZAKI EUROPE B.V. 12) Removing and Reattaching the Evaporator Cover The cover of evaporator can be removed and reattached for purpose of service according to the following procedure: Removing the Evaporator Box: Loosen the belts that secure the evaporator box and 1) There must be no traces of putty on the Evaporator Box carefully remove to avoid damage.
Page 33
HOSHIZAKI EUROPE B.V. 5) Make sure the sensor position is right Probes and inlet/outlet pipes which 6) There must be sheet plate under and suitable and drain path must be connected with Evaporator must cover the Defrost Heater to prevent plastic checked.
HOSHIZAKI EUROPE B.V. 13) Measures for Taking the Cabinet Out of Operation for Long Periods • Disconnect the power plug from the socket or switch off the circuit fuse. • Remove all foods from the cabinet. • Clean the cabinet (see cleaning section).
OrderSE@hoshizaki.dk Hoshizaki Italia – Italia TEL: +39 348 3022156 commerciale@hoshizaki.it Hoshizaki Europe B.V – All other countries in Europe and Africa TEL: +31 (0)20 691 84 99 sales@hoshizaki.nl -- http://hoshizaki-europe.com/ In the event of faults, please first check if the cabinet is connected to the mains, then check the fault indicator on the display and consult the service manual.
Equivalent 0,24 0,24 0,24 0,345 Heavy-duty; This appliance is intended for use in ambient temperatures up to 40°C Contact Details: HOSHIZAKI EUROPE B.V. Address: Burgemeester Stramanweg 101 1101 AA Amsterdam, The Netherlands Tel.: +31 (0)20 691 84 99 - http://hoshizaki.europe.com/...
Page 37
Equivalent 0,24 0,24 0,24 0,255 Heavy-duty; This appliance is intended for use in ambient temperatures up to 40°C Contact Details: HOSHIZAKI EUROPE B.V. Address: Burgemeester Stramanweg 101 1101 AA Amsterdam, The Netherlands Tel.: +31 (0)20 691 84 99 - http://hoshizaki.europe.com/...
Page 38
Equivalent 0,24 0,24 0,24 0,255 Heavy-duty; This appliance is intended for use in ambient temperatures up to 40°C Contact Details: HOSHIZAKI EUROPE B.V. Address: Burgemeester Stramanweg 101 1101 AA Amsterdam, The Netherlands Tel.: +31 (0)20 691 84 99 - http://hoshizaki.europe.com/...
Need help?
Do you have a question about the PREMIER 70 and is the answer not in the manual?
Questions and answers