Winter operation
Switching on:
Switching off:
Summer operation
10.2.3
Reisemobil - 06/02-2 - GLO-0005-00EN
The power supply of the heater cannot be interrupted by means of the 12 V
main switch.
The heater selects the necessary burner setting according to the required
room temperature. When the required room temperature is reached, the
burner is switched off. The room temperature is measured by the temperature
sensor next to the panel. In "Heater and boiler" operating mode (Fig. 54,6)
water in the boiler is also heated. In the operating mode "Heater without boiler"
(Fig. 54,5) the heater can be operated with an empty boiler.
Open the regulator tap on the gas bottle and the gas isolator tap "Heater/
boiler".
Turn the temperature control knob (Fig. 54,1) on the operating unit to the
desired heating level.
Set rotary switch (Fig. 54,3) to winter operation "Heater without boiler"
(Fig. 54,5) or to winter operation "Heater and boiler" (Fig. 54,6).
Green indicator lamp (Fig. 54,7) is on.
The circulation fan automatically switches on when the heater is activated.
Set the rotary switch (Fig. 54,3) to " " (Fig. 54,4).
Close the gas isolator tap "Heater/boiler" and the regulator tap on the gas
bottle.
After switching off the heater, the circulation fan may still run for a moment to
use up the residual heat.
It is not possible to heat the vehicle in "Summer" operating mode. In "Summer"
operating mode, only the water in the boiler is heated.
Further information can be obtained from the separate "Gas heater"
instruction manual.
For further information about the use of the boiler see section "Boiler".
Heater for waste water tank and waste water pipes (winter
comfort package)
In order to prevent waste water fittings freezing up, the waste water tank and
the waste water pipes can be electrically heated separately.
When the heater is turned on, temperature sensors monitor the temperature
of the waste water tank and the waste water pipes. If the temperature falls
below 5 °C, the heating elements are switched on and the waste water tank
and waste water pipes are heated. If the temperature rises above a certain
level, the heating elements are switched off again.