IMPORTANT INSTRUCTIONS - OPERATING MANUAL
FAS, QFAM
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel
and lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration,
and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6728076 Rev. Q 3/22
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) This unit must be grounded.
e) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
f) Read all instructions before installing or using exhaust fan.
g) For residential installations only.
h) Must use suitable weather hood with insect screen to protect air intake.
WARNING:
ANY SHIPPING MATERIAL THAT MAY BE PRESENT INSIDE
THE UNIT.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE
AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST,
STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE,
AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE
ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH
EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Inline Fan
FOR GENERAL VENTILATING USE ONLY.
TO REDUCE THE RISK OF FIRE, REMOVE
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY
SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FAS and is the answer not in the manual?

Questions and answers

Summary of Contents for AirKing FAS

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL FAS, QFAM Inline Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS SECTION 3 Ducting CAUTION: MAKE SURE POWER IS SWITCHED NOTE: 6” OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL SECTION 1 BUILDING CODES.
  • Page 3 SECTION 7 2. Pull the loose black, white and green wires out from the wire compartment (additional wires will be present). Install an approved electrical connector to the wire compartment cover (not Completing the Installation included). Run a black (hot), white (neutral), and a green or bare ground wire from the supply NOTE: When fan is mounted inline and no penetration is made into unconditioned spaces, there through the electrical connector.
  • Page 4 SECTION 9 (QFAM) SECTION 10 Setting the Controller Use and Care (Energy Savings Mode Only) CAUTION: Control Cover Control Panel If the main Access Panel has MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. not already been removed, remove the screws securing Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan.
  • Page 5: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate. 1a. Control setting. 1a. Check temperature and humidity level settings. If the intake air is not within the preset range, the fan will not turn on. Either adjust the settings or wait for the intake air temperature and/or humidity to change.
  • Page 6: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Mounting Brackets 5S1650001 6" Metal Collar (Intake) 5S1650002 6" Metal Collar (Outlet) 5S1650003 Blower Assembly 5S2202013 Wire Compartment Assembly 5S1650100 Adjustment Knobs 5S1299802 LCD Controller (QFAM) 5S1650043 Insect Screen 5S1650005 Access Panel 5S1650044 www.airkinglimited.com 6728076 Rev.
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION QFAM, FAS Ventilateur en série LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 INSTRUCTIONS D’INSTALLATION SECTION 3 ATTENTION : Conduit VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE. SECTION 1 ATTENTION: TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AVEC LES Préparation du Ventilateur CODES DU BATIMENT LOCAUX ET NATIONAUX...
  • Page 9 SECTION 7 2. Retirez les fils noirs, blancs et verts détachés du compartiment des câbles (des fils supplémentaires seront présents). Installez un connecteur électrique approuvé sur le Complétion de l’installation couvercle du compartiment des câbles (non inclus). Faites passer un fil noir (chaud), blanc (neutre) et un fil de terre vert ou nu de l’alimentation à...
  • Page 10 SECTION 9 (QFAM uniquement) SECTION 10 Utilisation et entretien Régler le contrôleur (mode économie d’énergie uniquement) ATTENTION : Si le panneau d’accès VOUS ASSURER QUE L’ALIMENTATION EST Couvercle du principal n’est pas déjà COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. panneau de contrôle Panneau de commande complètement enlevé,...
  • Page 11: Guide De Dépannage

    Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne. 1a. Paramètres de contrôle. 1a. Vérifiez les paramètres de température et d’humidité. Si l’air d’admission ne se trouve pas dans la plage préréglée, le ventilateur ne s’allumera pas Réglez les paramètres ou attendez que la température de l’air d’admission et / ou l’humidité...
  • Page 12: Schéma Des Pièces De Rechange

    SCHÉMA DES PIÈCES DE RECHANGE Qte. Description # de pièce remplacemen Support de montage 5S1650001 Assemblée de collier en métal de 6 po (d’admission) 5S1650002 Assemblée de collier en métal de 6 po (sortie) 5S1650003 Assemblée de la Soufflante 5S2202013 Assemblée du compartiment du fil 5S1650100 Boutons de réglage...

This manual is also suitable for:

Qfam

Table of Contents