AirKing ASLC50 Operating Manual

AirKing ASLC50 Operating Manual

Exhaust fan with light

Advertisement

IMPORTANT INSTRUCTIONS -

:
ASLC50, ASLC50FL,
Models
ASF50, ASLC70, ASF70

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
210572120 Rev. D 7-06
OPERATING MANUAL

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING:
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
10. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or
shower.
WARNING:
www.airkinglimited.com
Exhaust Fan with Light
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE IN KITCHENS
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASLC50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AirKing ASLC50

  • Page 1: Important Instructions

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL ASLC50, ASLC50FL, Models Exhaust Fan with Light ASF50, ASLC70, ASF70 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. Housing SECTION 1 Preparing the Exhaust Fan Joist 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: Mounting Rails 1 - Grill with Light Lens Figure 3...
  • Page 3 Supply Ground from house White Hot (Black) Hot (Red) Figure 8 Figure 6 SECTION 4 2. Wiring Fan/Light together: Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), Ducting one ground (green or bare copper), and one hot (black lead CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL connected to the switch).
  • Page 4 Secure the assembly to the reflector bolt using Tabs the acorn nut and lock washer. Install the appropriate bulb (not included) specific to your model: ASLC50/ASLC70: 100 watt maximum, type A19 medium base incandescent bulb. ASLC50FL: 13 watt maximum, 2 pin quad, compact flourescent bulb.
  • Page 5: Limited Warranty

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker. 1b. Connector plug from motor is not plugged in. 1b.
  • Page 6 Polarized Nylon Receptacle 2P 5S1201012 Grill 5S1201016 #10 Machine Screw 5S1201013 Lens 5S1201017 ASLC Motor Clip 5S5201001 Lamp Holder - ASLC50/ASLC70 5S1201018 #10 Lock Washer 5S1999007 Ballast - ASLC50FL 5S1201022 #10 Acorn Nut 5S1999008 Ballast - ASF50/ASF70 5S1201023 Motor - ASLC50/ASLC50FL/ASF50...

This manual is also suitable for:

Aslc50flAsf50Aslc70Asf70

Table of Contents