AirKing QuFresh QFAM Series Operating Manual

AirKing QuFresh QFAM Series Operating Manual

Inline fan
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT INSTRUCTIONS -
QFAM
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6728076 Rev. M 4-19
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
TM
by
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) This unit must be grounded.
e) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
f) Read all instructions before installing or using exhaust fan.
g) For residential installations only.
h) Must use suitable weather hood with insect screen to protect air intake.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Inline Fan
FOR GENERAL VENTILATING USE ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QuFresh QFAM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AirKing QuFresh QFAM Series

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL QFAM Inline Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    SECTION 3 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND SECTION 1 NATIONAL BUILDING CODES. Preparing the Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air Unpack fan from the carton and confirm that all pieces are present.
  • Page 3: Rocker Switch

    SECTION 7 Pull the loose black, white and green wires out from the wire compartment (additional wires will be present). Install an approved electrical connector to the wire compartment Completing the Installation cover (not included). Run a black (hot), white (neutral), and a green or bare ground wire from the supply through the electrical connector.
  • Page 4: Troubleshooting Guide

    SECTION 10 Press the “CONFIGURE” button again to set the upper limit temperature. This is the temperature that when the outside air coming into the home exceeds, the fan will stop Optional Motorized Damper and enter sampling mode. You will see “Upper Limit” and “Temperature” on the right hand side.
  • Page 5: Limited Warranty

    LIMITED WARRANTY WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials. HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for three (3) years from the date of original purchase or until the original purchaser of the product sells or transfers the product, whichever first occurs.
  • Page 6: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM High Qty. Description Replacement Part # Mounting Brackets 5S1650001 6" Metal Collar (Intake) 5S1650002 6" Metal Collar (Outlet) 5S1650003 Blower Assembly 5S2202013 Wire Compartment Assembly 5S1650100 Adjustment Knobs 5S1299802 LCD Controller 5S1650004 Insect Screen 5S1650005 Filter Access Panel 5S1650034 Main Access Panel 5S1650035...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Ventilateur d’évacuation QFAM en série LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 3 INSTRUCTIONS D’INSTALLATION Conduit ATTENTION: VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION: SECTION 1 TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AVEC LES CODES DU BATIMENT LOCAUX ET NATIONAUX.
  • Page 9 SECTION 7 Retirez les fils noirs, blancs et verts détachés du compartiment des câbles (des fils supplémentaires seront présents). Installez un connecteur électrique approuvé sur le Complétion de l’installation couvercle du compartiment des câbles (non inclus). Faites passer un fil noir (chaud), blanc (neutre) et un fil de terre vert ou nu de l’alimentation à...
  • Page 10: Guide De Dépannage

    SECTION 10 Appuyez sur le bouton haut ou bas pour afficher la température en degrés Fahrenheit ou Celsius. Amortisseur motorisé optionnel Appuyez à nouveau sur le bouton « CONFIGURE » pour régler la température limite Un amortisseur motorisé optionnel MD624 (vendu séparément) peut être ajouté à l’unité. supérieure.
  • Page 11: Garantie Limitée

    GARANTIE LIMITÉE QUE COUVRE CETTE GARANTIE : Ce produit est garanti contre tout vice de fabrication ou de matière. COMBIEN DE TEMPS CETTE GARANTIE DURE : Cette garantie se rapporte seulement à l’acheteur original du produit et dure pendant trois (3) années de la date de l’achat original ou jusqu’à...
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT High # de pièce Qté. Description remplacement Support de montage 5S1650001 Assemblée de collier en métal de 6 po 5S1650002 (d’admission) Assemblée de collier en métal de 6 po 5S1650003 (sortie) Assemblée de la Soufflante 5S2202013 Assemblée du compartiment du fil 5S1650100...

This manual is also suitable for:

Qufresh mfas series

Table of Contents