Remote Logoff; Table 13. Alarm History Fields And Descriptions - ADC HRU-419 HiGain User Manual

Remote unit
Table of Contents

Advertisement

Installation

Table 13. Alarm History Fields and Descriptions

Field
Description
Type
Identifies the type of alarm.
LOS,
First and last instance of LOS at the HLU; Current condition, number of
DS1-HLU
alarms.
LOS,
First and last instance of LOS at the HRU; Current condition, number of
DS1-HRU
alarms.
Span 1
First and last instance of LOSW on HDSL1; Current condition, number of
LOSW,
alarms.
HDSL1
Span 1
First and last instance of LOSW on HDSL2; Current condition, number of
LOSW,
alarms.
HDSL2
Span-1 ES,
First and last instance of ES on HDSL1; Current condition, number of
HDSL1
alarms.
Span 1 ES,
First and last instance of ES on HDSL2; Current condition, number of
HDSL2
alarms.
Span 1
First and last instance of exceeded margin on Loop 1; Current condition,
Margin L1
number of alarms.
Span 1
First and last instance of exceeded margin on Loop 2; Current condition,
Margin L2
number of alarms.
PWR Open
Power condition: Open or Closed.
PWR SHRT
Power short condition.
Last Cleared:
Last time Alarm History cleared.
None

Remote Logoff

H
Press
from the Remote Terminal Main Menu to log off the system. The
Remote Logoff screen displays indicating that you have logged off the
HRU-419.