Download Print this page

Sony DCR-SR32E Manual page 52

Hide thumbs Also See for DCR-SR32E:

Advertisement

5. G Sensor Check
Click the [G Sensor Check] button on the SERVICE MODE screen,
and the following screen will appear.
If the [Reset] button is clicked, the Camcorder is reset and it is
restarted, and then the "G SENSOR CHECK" screen will appear.
Using method:
Click the [Start] button, and the G sensor check will start.
During execution of G sensor check, the conditon of G sensor is
displayed.
Click the [Top] button, and the following message will be displayed.
If the [OK] button is clicked, and Camcorder is reset and it is re-
started, and then the SERVICE MODE screen will come back.
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
6. Record Data
Click the [Record Data] button on the SERVICE MODE screen,
and the "RECORD DATA" screen will appear.
The record data such as use record and self-diagnostic record are
displayed.
Initializing method (Self-Diagnosis Data Only):
Click the [Clear Self-Diagnosis Data Only] button on the screen, and
the Self-Diagnosis Data will be initialized.
Initializing method (All Record-Data):
Click the [Clear All Recorded-Data] button on the screen, and the
All Recorded-Data will be initialized.
Note: Performing the initialization causes all the user settings
including time setting to be initialized, too.
6-50
Ver. 1.5 2007.09

Advertisement