Fisher FSK-180B-EU Operating And Installation Instruction Manual page 56

Cassette type air conditioner (with wire controller)
Table of Contents

Advertisement

Caution:
(1) Do not wrap the protective tape too tight, otherwise the efficiency of thermal insulation
may be decreased. Ensure that the condensate drainage flexible tube is separate from the
bundled pipes.
(2) After the protective work is completed and the pipes are wrapped, use seal material to
block the hole in the wall, so as to prevent rain and wind from entering the room.
G、Position and Method of Installing Wire Controller
1、First select an installation position. According to the size of the communication line of the
wire controller, leave a recess or a embedded wire hole to bury the communication line.
2、If the communication line between the wire controller (85 ×85 ×16) and the indoor unit is
surface-mounted, use 1# PVC pipe and make matching recess in the wall (refer to Figure 6);
If concealed installation is adopted, 1# PVC pipe can be used (Refer to Figure 7).
3、No matter if surface mounting or concealed mounting is selected, it is required to drill 2
holes (in the same level) which distance shall be the same as the distance (60mm) of
installation holes in the bottom plate of the wire controller. Then insert a wood plug into
each hole. Fix the bottom plate of the wire controller to the wall by using the two holes.
Plug the communication line onto the control panel. Lastly install the panel of the wire
controller.
Caution:
1.During the installation of the bottom plate of the wire controller, pay attention to the
direction of the bottom plate. The plate's side with two notches must be at the lower position, and
otherwise the panel of the wire controller cannot be correctly installed.
PVC Pipe
PVC管
Fig 6 Surface Mounting of Cable
Fig 7 Concealed mounting of Cable
53
1
Fig 8 Schematic Diagram of Installation
2
3
4