Winload Connection; Universal In-Field Programmer Connection; X10 Transmitter Connection (Mg-6160 Only); Connecting A Paradox Memory Key (Pmc-3) - Paradox Magellan MG-6130 Reference And Installation Manual

All-in-one wireless security system v2.0
Table of Contents

Advertisement

WinLoad Connection

The Magellan console can be programmed and monitored
through the WinLoad Installer Upload/Download Software for
Windows®. WinLoad allows for remote or on-site uploading and
downloading using most standard modems. It also allows for
advanced printing of reports and supports several languages
simultaneously. Connect Magellan to a computer containing the
WinLoad software as shown in Figure 10 on page 10.
Refer to the WinLoad's Online Help for more information
on WinLoad.
Figure 10: On-site Connection
Back view of the
Magellan console.
4- to 10-pin cable
(supplied with
the 306 Adapter)
Computer
containing
WinLoad
software
UIP-256 Universal In-Field Programmer
Connection
Magellan's firmware can be upgraded locally using the UIP-256
Universal In-Field Programmer. The UIP-256 includes
proprietary PC software, cables to interconnect Magellan and a
PC, as well as two 9V batteries. Connect the UIP-256 as shown
in Figure 11 on page 10.
Refer to the Universal In-Field Programmer (UIP-256)
Instructions for more information.
10
4-pin
connector
cable
306 Adapter
Standard
DB-9 cable
(9-pin serial cable)
Figure 11: Connecting the UIP-256
Connect the 10-pin
cable of the UIP-256 to
the 10-pin connector of
the Magellan console.
UIP-256
Universal In-Field
Programmer
Standard
DB-9 cable
(9-pin serial cable)

X10 Transmitter Connection (MG-6160 only)

Magellan supports the X10 communication protocol. X10 is a
communication protocol for remote control of electrical devices
such as lamps and appliances. Communication is accomplished
through standard household electrical wiring using X10
transmitters and receivers. Configure Magellan, with the use of
an X10 transmitter, to automate a home. Connect the X10
transmitter as shown in Figure 12 on page 10.
Refer to the Magellan X10 Instructions on our website,
paradox.com, for information on using and configuring
Magellan's X10 feature.
Figure 12: Connecting the X10 Transmitter
Back view of the Magellan console.
1
4-pin
RJ11
cable
The X10 feature is not for use in UL installations.

Connecting a Paradox Memory Key (PMC-3)

When using a Paradox Memory Key with a Magellan console,
remove power (both AC and battery power) and connect the
memory key to the 5-pin connector on the back of the Magellan
console as shown in Figure 13 on page 11. Once connected, re-
Back view of the
Magellan console.
Download latest
Magellan
firmware from
paradox.com
1. Connect one end of the
4-pin RJ11 cable into the
10 plug of the console.
X
2. Connect the other end of
the 4-pin RJ11 cable into
the X10 transmitter.
3. Plug the X10 transmitter
into a standard wall
outlet.
3
X10 transmitter
2
Reference & Installation Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magellan mg-6160

Table of Contents