through two mounting holes.
Drill two 3/16- - in (4.8 mm) mounting holes in wall where marked.
S
Secure mounting plastic to wall using two screws and anchors provided.
S
Adjust length and routing of each wire to reach each wire entry on the
S
connector backplate. Strip 1/4- - in (6.4 mm) of insulation from each wire.
Match and connect thermostat wires to proper terminals on control backplate.
S
See wiring diagrams in Section 8.0.
d
Push any excess wire into the wall. Seal hole in wall to prevent any air leaks.
S
Air leaking from behind the wall can affect measured temperature and
humidity, and can affect operation.
Attach Evolution Connex Control to the mounting plastic by lining up the
S
plastic guides on the back of the control with the opening on the mounting
plastic and push on.
Perform installation of all other system equipment (i.e. dampers, humidifier,
S
ventilator, UV lights, etc.). See the equipment and device installation
instructions for details.
Turn on power to equipment.
S