GasAlertMicroClip
Quick Reference Guide
Alarms
Alarm
Display
Low Alarm
Slow siren
Slow alternating flash
llmlDI and gas bar flash
Vibrator alarm activates
High Alarm
-'fi.1D9D
Fast siren
17
Fast alternating flash
,20�-
llmlDI and gas bar flash
Vibrator alarm activates
Multi-Gas Alarm
Alternating low and high alarm siren and
D
flash
, i � -
llmlDI and gas bars flash
Vibrator alarm activates
If Stealth mode is enabled, the audible and visual alarms are
disabled. Only the vibrator alarm activates ..
Alann
Display
TWAAlarm
Slow siren
Slow alternating flash
llmlDI and gas bar flash
Vibrator alarm activates
STELAlarm
Fast siren
Fast alternating flash
llmlDI and gas bar flash
Vibrator alarm activates
Over Limit (OL) Alarm
-'fi.1D9D
Fast siren and alternating flash
D
llmlDI and gas bar flash
20 � - □t:
Vibrator alarm activates
OL displays
Alarm
Sensor Alarm
During startup Error [sensor name]
.
displays
During normal operation Err displays
Low B attery Alarm
Sequence of 10 rapid sirens and
alternating flashes with 7 seconds of
silence in between (continues for
15 minutes)
=::JI and !lmlDI flash, LOW BAT
displays, and the vibrator alarm activate,
After 15 minutes of the Low Battery
D
alarm, the Automatic Shutdown Alarm
sequence begins
OFF displays before deactivating
Display
Alann
Confidence B eep and lntelliFlash
One beep and flash every second
Note: Confidence Beep and
.. Q
(,-,-
20�-
lntelliFlash automatically
IJ
deactivate during low battery
alann, self-test fail, calibration fail,
or
bump test fail,
an alann event.
Automatic Shutdown Alarm
Sequence of 1 O rapid sirens and
alternating flashes with 1 second of
silence in between (sequence reactivates
seven times)
!
L, 'fi.1D9D
LOW BAT and l!!!.'!i display, and
.
H
I�
vibrator alarm activates
J' : : D '\ Di
I
OFF displays before deactivating
120�� .. Cl
'Note: Alarms can be set to latching or non-latching. To enable/disable
atching, select/deselect
Latching Alarms
regulations may require
latching alarm.
a
/flow Alarm Acknowledge is
enabled and
disable the audible alarm. The visual and vibrator alarms remain
'.) lo
activated.
the alarm escalates
lo a
If
audible alarm reactivates.
GasAlertMicroClip
Alarms
Display
a
D
oe:
20� -
'fi.1D9D
LOW
BRT,
in Fleet Manager II. Local
a
low alarm occurs, press
high, STEL,
1WA alarm, the
or

Advertisement

loading
Need help?

Need help?

Do you have a question about the GasAlertMicroClip XT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BW Technologies GasAlertMicroClip XT

  • Page 1 GasAlertMicroClip GasAlertMicroClip Quick Reference Guide Alarms Alarms If Stealth mode is enabled, the audible and visual alarms are Alarm Display Alann Display disabled. Only the vibrator alarm activates .. Sensor Alarm Confidence B eep and lntelliFlash Alarm Display Alann Display During startup Error [sensor name] One beep and flash every second displays...
  • Page 2 GasA/ertMicroC/lp • It is recommended that the combustible sensor be Quick Reference Guide checked with a known concentration of calibration gas GasAtertMicroCl/p after any exposure to contaminants/poisons such as, XL and X3 Safety Information Read First Parts of the GasAlertMicroC/ip sulfur compounds, silicon vapors, halogenated compounds, etc.

This manual is also suitable for:

Gasalertmicroclip xlGasalertmicroclip x3