BW Technologies GasAlertMicro 5 Quick Reference Manual

O2, co, h2s, ph3, so2, cl2, nh3, no2, hcn, clo2, o3, voc, and combustibles. 1, 2, 3, 4, and 5 gas detectors
Hide thumbs Also See for GasAlertMicro 5:

Advertisement

GasAlertMicro 5 and
GasAlertMicro 5 PID
O
, CO, H
S, PH
, SO
, Cl
, NH
, NO
, HCN, ClO
, O
, VOC, and Combustibles
2
2
3
2
2
3
2
2
3
1, 2, 3, 4, and 5 Gas Detectors
Quick Reference Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GasAlertMicro 5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BW Technologies GasAlertMicro 5

  • Page 1 GasAlertMicro 5 and GasAlertMicro 5 PID , CO, H S, PH , SO , Cl , NH , NO , HCN, ClO , VOC, and Combustibles 1, 2, 3, 4, and 5 Gas Detectors Quick Reference Guide...
  • Page 2 Limited Warranty & Limitation of Liability BW Technologies LP (BW) warrants this product to be free from defects in material and workmanship under normal use and service for a period of two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer.
  • Page 3: Safety Information - Read First

    This quick reference guide provides basic information for the Use the detector only as specified in this guide, otherwise GasAlertMicro 5 and GasAlertMicro 5 PID. Refer to the user the protection provided by the detector may be impaired. manual on the accompanying CD-ROM for complete operating Read the following Cautions before using the detector.
  • Page 4 ⇒ Extended exposure of the GasAlertMicro 5 and a gas concentration that exceeds the alarm GasAlertMicro 5 PID to certain concentrations setpoints. Manually verify that the audible and of combustible gases and air may stress a visual alarms are activated.
  • Page 5 GasAlertMicro 5 & GasAlertMicro 5 PID Parts of the GasAlertMicro 5 & GasAlertMicro 5 PID Parts of the GasAlertMicro 5 & GasAlertMicro 5 PID Item Description Visual alarm bars (LED) Toxic 1/PID sensor Toxic 2 sensor LEL sensor Audible alarms...
  • Page 6: Display Elements

    GasAlertMicro 5 & GasAlertMicro 5 PID Quick Reference Guide Display Elements Item Description Alarm condition Automatically span sensor Gas cylinder Gas identifier bars Battery life indicator Pass code lock Data transmission Clock Stealth mode Optional pump indicator Optional datalogger card indicator...
  • Page 7 GasAlertMicro 5 & GasAlertMicro 5 PID Pushbuttons Pushbuttons Pushbutton Description • To turn on the detector press A. • To turn off the detector, press and hold A until the countdown is complete. • To increment the displayed value or scroll up, press G.
  • Page 8 GasAlertMicro 5 & GasAlertMicro 5 PID Quick Reference Guide Calibration Procedure Display Procedure Display 1. In a clean atmosphere, press and hold 4. This option allows the user to select C and H simultaneously (as the which sensor to span. Use G and H...
  • Page 9 GasAlertMicro 5 & GasAlertMicro 5 PID Attach the Gas Cylinder to the Detector Attach the Gas Cylinder to the Detector Procedure Display 7. Press H or G to change the calibration due date. Press C to accept this value and proceed to the next due date.
  • Page 10 GasAlertMicro 5 & GasAlertMicro 5 PID Quick Reference Guide Alarms The following table lists the numerous alarms of the detector. Alarm Display Alarm Display Low Alarm: TWA Alarm: • • Fast beep Fast beep • • Slow flash Slow flash •...
  • Page 11 GasAlertMicro 5 & GasAlertMicro 5 PID Alarms Alarm Display Alarm Display Multi-Gas Alarm: Over Range Alarm: (Over Level Exposure) • Alternating low and high alarm • beep and flash Fast beep and flash • • L and target gas bars flash L and target gas bar flash •...
  • Page 12 GasAlertMicro 5 & GasAlertMicro 5 PID Quick Reference Guide Alarm Display Alarm Display Confidence Beep: Pump Alarm: • • One beep, one flash, and one Screen flashes: vibrate every 10 seconds - Pump flow change detected - Check for blocked inlet - or press C to run a pump test •...
  • Page 13: User Options Menu

    GasAlertMicro 5 & GasAlertMicro 5 PID User Options Menu • Safe: Enables the display to read Safe if the detector User Options Menu does not enter an alarm; To access the user options menu press and hold G and H •...
  • Page 14: Maintenance

    GasAlertMicro 5 & GasAlertMicro 5 PID Quick Reference Guide • %vol CH Maintenance : Shows the LEL reading in % vol. assuming a methane environment; To keep the detector in good operating condition, perform • Correction: Allows the user to adjust the instrument...
  • Page 15 GasAlertMicro 5 & GasAlertMicro 5 PID Maintenance Replacing the Batteries a Warning: Always turn off the detector before removing the battery pack. The battery packs are hot-swappable, but alkaline batteries inside the pack must be changed in a non-hazardous atmosphere.
  • Page 16: Specifications

    GasAlertMicro 5 & GasAlertMicro 5 PID Quick Reference Guide Replacing a Sensor or Sensor Filter Item Description Sensor cover Sensor filter Sensors Detector Machine screws (2) Specifications Instrument dimensions: 14.5 x 7.4 x 3.8 cm (5.7 x 2.9 x 1.5 in.) Weight: 370 g (13.1 oz.)
  • Page 17 GasAlertMicro 5 & GasAlertMicro 5 PID Specifications Alarm setpoints: May vary by region and are user-settable Audible alarm: 95 dB at 1 ft. (0.3 m) variable pulsed dual beepers Detection range: Visual alarm: Dual red light-emitting diodes (LED) : 0 – 30.0% vol. (0.1% vol. increments) CO: 0 –...
  • Page 18 GasAlertMicro 5 & GasAlertMicro 5 PID Quick Reference Guide ATEX: CE 0539 g II 1 G EEx ia IIC Approved batteries Approved batteries for product (standards IEC 60079-11, KEMA 05ATEX 1096X EN50020, UL913, C22.2 No. 157) IECEx: Ex ia IIC...
  • Page 20 D5614/6 English iERP: 123020 © 2006 BW Technologies. All rights reserved. Printed in Canada. All product names are trademarks of their respective companies.
  • Page 21 Thank you for reading this data sheet. Please contact us for a quotation: Head Office (UK) Switzerland Office P.O. Box 2124 Zugerstrasse 46 Chelmsford 6314 Unterägeri Essex CM1 3UP England Switzerland Tel: +44 (0)1245 600 560 Tel: +41 41 541 5877 Fax: +44 (0)1245 600 030 Fax: +41 41 541 5878 Email:...