Operation Instructions - UNINEX KOOLZONE SAC-3000 User Manual

Mobile spot cooler
Hide thumbs Also See for KOOLZONE SAC-3000:
Table of Contents

Advertisement

Installation of the heat duct and socket:
The heat duct socket uses 4 ST4×12 bolts to fix
on the heat vent.
When heat duct insertion heat duct socket,
please note reliably.
Power supply connection
Please use exclusive power supply
When you have to use an extension wire, please be sure to use it
according to the following list. The machine will not operate normally
if the extended wire was too long or too thin.
Length of the wire
Within 8M
Within 20M
Please use earth leakage circuit breaker with 15A 30MA ,within 0.1S action time.
Please use earth wire with section 1.5mm .

6. Operation Instructions

Turn on the choice switch in front of the machine
for the operation, there are 3 choices (off,low,high)
for control.
Note: Turn off the machine and cut the electricity before
moving the machine.
After 3 minutes of turning off ,then re-turn on it ,
otherwise the peotectiong process will let machine
no work.
Overload relay used for compressor
If there is over-current or over heating,
over load relay will operate to protect the compressor.
Attention: The machine will only blow nature wind while
the relay acted.
Wind direction adjustment
In order to get your satisfied direction of cooling duct
and heat duct, please adjust the duct.
The adjustment range of cooling duct is 200 degrees
in horizontal 50 degrees in vertical level.
The adjustment range of heat exhaust duct is 40 degrees.
Heat exhaust duct is installed.
Attention
Please adjust the angle of cooling duct and heat exhaust
duct before operating the machine.Please hold the bending
duct not the cooling duct to adjust the angle.
Heat vent
Section area
4.0mm
2
6.0mm
2
2
Heat duct
Heat duct
socket
Choice switch
About 40°
About 50°
About 200°