UNINEX KOOLZONE SAC-25FC User Manual

UNINEX KOOLZONE SAC-25FC User Manual

Mobile spot cooler

Advertisement

Quick Links

USER MANUAL
SAC-25FC
FOR MORE INFO

Advertisement

Table of Contents
loading

Summary of Contents for UNINEX KOOLZONE SAC-25FC

  • Page 1 USER MANUAL SAC-25FC FOR MORE INFO...
  • Page 2 THANK YOU FOR PURCHASING THE KOOLZONE MOBILE SPOT COOLER. PLEASE READ THE INSTRUCTIONS BEFORE USING. KEEP THESE INSTRUCTIONS FOR REFERENCE. KOOLZONE...
  • Page 3 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ································ PAGE 4,5 2. SPECIFICATIONS ············································ PAGE 6 3. ACCESSORIES ················································ PAGE 6 4. PARTS OF THE MACHINE ································ PAGE 7 5. INSTALLATION ··············································· PAGE 7 6. OPERATING INSTRUCTION ····························· PAGE 9 7. MAINTENANCE AND INSPECTION ··············· PAGE 10 8.
  • Page 4: Safety Precautions

    1. SAFETY PRECAUTIONS Please read “Safety Precautions” carefully before operating the unit to reduce the risk of injury or damage. It may cause personal injury, fire, or other property damage STOP STOP if you neglect this mark and operate in the wrong way. This mark stands for under any circumstances this unit should FORBIDDEN not be used.
  • Page 5 Do not change or modify the unit. It could cause damage to the unit or property and will void STOP warranty. Keep unit away from excessive heat or fire. It may cause damage to the unit. Use only grounded outlet. The unit operates in the temperature range from 64°F to 104°F, otherwise it may cause the unit to slow the air flow or shutdown.
  • Page 6: Specifications

    2. SPECIFICATIONS POWER / FREQUENCY Single phase 115 V / 60 Hz Aircondition LOAD CURRENT 1.7 A 8.58 A CONSUMPTION POWER 195 W 937 W COOLING CAPACITY 9,210 BTU COMPRESSOR Fully Closed Type Rotary REFRIGERANT R410 A REFRIGERANT (RATED CHARGE) 520 g FAN PROTECTOR Inner Overheatprotector...
  • Page 7: Parts Of The Machine

    4. PARTS OF THE MACHINE Evaporator Filter Screen Heat Vent Cover Plate Heat Vent Front Cold Air Vent Socket Cooling Duct Electric Box Cover Plate Side Cold Air Vent Cover Plate Evaporator Filter Screen Switch Control Box Caster Wheel Power Cord 5.
  • Page 8 • INSTALLING THE DRAIN HOSE Connect the drain hose as illustrated below. Condensated water can be drained directly from the unit using the drain hose. Water Outlet Drain Hose • INSTALLING THE THE SWITCH CONTROL BOX The switch control box hook is attached to the side of the unit (as illustrated below). Connect the switch control box to the hook.
  • Page 9 6. OPERATING INSTRUCTION SWITCH CONTROL BOX OVERVIEW Stop Cooling Stop Cooling Stop Cooling STOP COOLING • HOW TO OPERATE AND SELECT FUNCTIONS Set the switch to fan mode and the fan will start. The unit will emit ambient air. At fan mode setting the compressor will not work. Set the switch on cooling mode, the compressor will start and cold air will flow from the AC unit.
  • Page 10: Maintenance And Inspection

    • KEEP DISTANCE Make sure the unit has minimum distance from any wall, ceiling, or object as illustrated below. Direction above 16” Direction Direction Direction above 16” above 16” above 16” Front In order to prevent accidents, the unit should be placed on level ground. Unlevel ground, stairs, emergency exits should not be used.
  • Page 11: Troubleshooting

    8. TROUBLESHOOTING PROBLEM CAUSE SOLUTION • Insert the plug into the wall outlet. • The power plug is loose or • Check breaker on main panel and reset. NOT RUNNING disconnected. • Ask the technical service department • The breaker switch has turned off. for assistance.
  • Page 12 KOOLZONE MANUFACTURER’S RECOMMENDATIONS 1. USE A DEDICATED OUTLET. DO NOT SHARE AN OUTLET WITH OTHER DEVICES. SHARING AN OUTLET MAY CAUSE A POWER OUTAGE. 2. IF USING AN EXTENSION CORD, A 12 AWG IS RECOMMENDED. 3. DO NOT BLOCK THE HEAT EXHAUST DUCT. BLOCKING THE HEAT EXHAUST COULD CAUSE THE UNIT TO OVERHEAT AND STOP WORKING PROPERLY.
  • Page 13 PLEASE NOTE OPTIMUM OPERATING TEMPERATURE RANGE FOR KOOLZONE MOBILE SPOT A/C COOLER IS FROM 77° - 113° FAHRENHEIT. WHEN USING THIS UNIT ON COOLING MODE, THE AMBIENT TEMPERATURE WILL BE REDUCED BETWEEN 10° - 15° FAHRENHEIT. KOOLZONE...
  • Page 14 MAKE LIFE SIMPLE AND MORE CONVENIENT WITH UNINEX SCAN ME CONTACT US FOR PURCHASE OR RENTAL EXCLUSIVELY DISTRIBUTED BY: UNINEX INTERNATIONAL 5780 SMITHWAY STREET COMMERCE, CA 90040 T. 800-864-3288 / 323-890-9246 / F. 323-890-9249 MANUFACTURE: NAKATOMI CO.,LTD. 6445-2, TAKAI, TAKAYAMA, KAMITAKAI, NAGANO, JAPAN...

Table of Contents