UNINEX KoolBase MSC1800NE User Manual

UNINEX KoolBase MSC1800NE User Manual

Mobile spot cooler

Advertisement

Quick Links

KoolBase
MOBILE SPOT COOLER
USER MANUAL
MSC1800NE

Advertisement

Table of Contents
loading

Summary of Contents for UNINEX KoolBase MSC1800NE

  • Page 1 KoolBase MOBILE SPOT COOLER USER MANUAL MSC1800NE...
  • Page 2 THANK YOU FOR PURCHASING THE KOOLBASE MOBILE SPOT COOLER. PLEASE READ THE INSTRUCTIONS BEFORE USING. KEEP THESE INSTRUCTIONS FOR REFERENCE. KoolBase...
  • Page 3 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ··································· PAGE 4,5 2. SPECIFICATIONS ················································· PAGE 6 3. ACCESSORIES ····················································· PAGE 6 4. PARTS OF THE MACHINE ··································· PAGE 7 5. INSTALLATION ····················································· PAGE 7 6. OPERATING INSTRUCTION ································ PAGE 8 7. MAINTENANCE AND INSPECTION ··················· PAGE 11 8.
  • Page 4: Safety Precautions

    1. SAFETY PRECAUTIONS Please read “Safety Precautions” carefully before operating the unit to reduce the risk of injury or damage. It may cause personal injury, fire, or other property damage STOP STOP if you neglect this mark and operate in the wrong way. This mark stands for under any circumstances this unit should FORBIDDEN not be used.
  • Page 5 Do not change or modify the unit. It could cause damage to the unit or property and will STOP void warranty. Keep unit away from excessive heat or fire. It may cause damage to the unit. Use only grounded outlet. The unit operates in the temperature range from 64°F to 104°F, otherwise it may cause the unit to slow the air flow or shutdown.
  • Page 6: Specifications

    2. SPECIFICATIONS POWER / FREQUENCY Single Phase 115 V / 60 Hz 5.6 A LOAD CURRENT CONSUMPTION POWER 675 W COOLING CAPACITY 6,100 BTU COMPRESSOR Fully Closed Type Rotary REFRIGERANT R410 A 340 g REFRIGERANT (RATED CHARGE) WATER STORAGE CAPACITY Condensation Tank / Drain Pipe CONDENSATE WATER HANDLING METHOD SIZE...
  • Page 7: Parts Of The Machine

    4. PARTS OF THE MACHINE Cooling Duct Operation Switch Filter Curved Duct Exhaust Condensation Tank (3L) Caster Wheel 5. INSTALLATION • INSTALLING THE CURVED DUCT Line up the nubs on the curved duct with slot on the cold air exit. Turn locking ring until lt is locked position.
  • Page 8 • POWER SUPPLY CONNECTION Please use a dedicated power outlet. Please use a grounded circuit breaker with a 15A capacity. Grounded Screw Power Cord 6. OPERATING INSTRUCTION OPERATION SWITCH INFORMATION Cooling • To power on, turn on the switch at the top of the unit to fan or cooling for operation. There are 2 options: 1.
  • Page 9 • COMPRESSOR OVERLOAD / OVERHEAT PROTECTION If the compressor overheats or overloads due to high or low voltage or high ambient temperature, the built in safety protection for the compressor will start working and turn off the unit. NOTIFICATION When the overload protection is working, the air flow from the unit will be at the ambient temperature of the room, but will not cool the air.
  • Page 10 • CONDENSATION TANK. The dehumidified water will flow into condensation tank. The capacity of the tank is 3L. The condensation tank can be taken out manually from the unit. NOTIFICATION Please check the amount of the water periodically. Drain the water before moving the unit. Empty the water immediately when the water gets to the red line.
  • Page 11: Maintenance And Inspection

    7. MAINTENANCE AND INSPECTION NOTIFICATION Please clean the filter regularly. • When cleaning filter with heavy use, consider vacumming filter before rinsing. Rinse with water and dry thoroughly before reuse. • When cleaning the surface of the unit, do not use abrasive materials or chemicals which could damage the unit surface.
  • Page 12: Troubleshooting

    8. TROUBLESHOOTING PROBLEM CAUSE SOLUTION • Insert the plug into the wall outlet. • The power plug is loose or • Check breaker on main panel and disconnected. NOT RUNNING reset. • The breaker switch has turned • Ask the technical service off.
  • Page 13 KOOLBASE MANUFACTURER’S RECOMMENDATIONS 1. USE A DEDICATED OUTLET. DO NOT SHARE AN OUTLET WITH OTHER DEVICES. SHARING AN OUTLET MAY CAUSE A POWER OUTAGE. 2. IF USING AN EXTENSION CORD, A 12 AWG IS RECOMMENDED. 3. DO NOT BLOCK THE HEAT EXHAUST DUCT. BLOCKING THE HEAT EXHAUST COULD CAUSE THE UNIT TO OVERHEAT AND STOP WORKING PROPERLY.
  • Page 14 PLEASE NOTE OPTIMUM OPERATING TEMPERATURE RANGE FOR KOOLBASE MOBILE SPOT A/C COOLER IS FROM 64 - 104° FAHRENHEIT. PROPER USAGE OF THIS UNIT, AT THE COOLING DUCT, WILL REDUCE THE AMBIENT TEMPERATURE BETWEEN 10 - 15° FAHRENHEIT. KoolBase...