Summary of Contents for 3Shape TRIOS S3P-2

  • Page 1 3Shape TRIOS Safety and Setup Guide S3P-2, S3P-8, S3A-10, S3A-14, S3A-18, S3A-22 04-2021...
  • Page 2: Table Of Contents

    Thank you for purchasing your TRIOS® intraoral scanner (IOS) system from to prevent personal injury, material damage or damage 3Shape TRIOS A/S . The TRIOS IOS system enables you to perform and digitally to your TRIOS system . Safety information and warnings save oral scans of patient’s teeth for use in dental CAD/CAM systems .
  • Page 3: Description Of Trios

    Electrical insulation Class II WEEE Product disposal symbol Medical Device Caution Global Trade Item Number CE marking Prescription Only (applicable for United States of America) Lot number Model Number Serial Number 4. Description of TRIOS Consult instructions for use 4.1 Certification and Compliance Notes Alternating Current CE marking Protective earth (ground)
  • Page 4 The scanner tip as well as the protection tip (S4) can be attached by the following procedure: The 3Shape TRIOS 4 IOS system is intended to obtain 3D digital images 1 . Place the tip over the front tube with the mirror facing upwards of the topographical characteristics of teeth, including bite, gingivae and or downwards .
  • Page 5 • USB wireless dongle (allows communication between scanner and System S3A (MOVE/MOVE+ cart) only computer or cart) • USB license dongle (access to 3Shape Software) Please follow the steps below for assembling TRIOS IOS system (Figure 5): • USB wifi dongle (for connecting cart to wifi network) Step 1: Place the MOVE/MOVE+ cart optimally in relation to the patient •...
  • Page 6 . install the TRIOS software first . In case of difficulties with software instal- lation, plase contact 3Shape support . Step 2: Log on using a default TRIOS Operator . System S3A (MOVE/MOVE+ cart) only Step 3: Configure and use your TRIOS IOS system .
  • Page 7: Safety And Warnings

    S3-2 scanners . Wireless- battery powered CAUTION S3-2 scanners . Wired- TRIOS 4 cord Install only approved software – to prevent interference 3Shape TB-02 Rechargeable Battery with the runtime reliability of the system and programs 3,6 V, 2000 mAh, 7 Wh within it .
  • Page 8 In case of equipment failure WARNING If the handheld scanner is dropped, examine the TRIOS WARNING IOS system for any mechanical damage . If a mechanical If at any time the TRIOS IOS system malfunctions, damage is observed or suspected, treat this as an equip- or if you suspect in any way that the TRIOS IOS system ment failure (see this guide’s instructions on handling is not working correctly:...
  • Page 9 5.4 Electrical Safety Condensation WARNING Ensure a grounded/earthed connection Variations in temperature or humidity may cause water to condense inside the system, which can cause damage . WARNING Always let the system reach room temperature before you To avoid the risk of electric shock, the MOVE/MOVE+ cart plug it into the power source .
  • Page 10: Cleaning, Disinfection, And Sterilization

    5.5 Eye safety 5.7 Safety when scanning with TRIOS WARNING CAUTION The scanner emits bright light from its tip during operation . The handheld scanner is a highly precise optical instrument The scanner complies with EN (IEC) 62471 (Photobiological and must be handled carefully . Do not drop, shake or bump safety of lamps and lamp systems) .
  • Page 11 High-level disinfection with Wavicide-01 Solution as an and manufacturer of the autoclave . Please refer to the user manual alternative to sterilization has been validated by 3Shape . of the autoclave manufacturer to verify that the minimum autoclave parameters are met .
  • Page 12: Disposal

    Do not spray directly onto any parts of the system, as the liquid solution can accumulate at the seals For disposal of the TRIOS IOS system, please contact your 3Shape reseller, who and leak into the scanner, monitor, PC, cords, or pod .
  • Page 13: Technical Maintenance

    When the scanner tips are disposed, new tips can be ordered by contacting must be performed by 3Shape or 3Shape-authorized your 3Shape reseller . Also, a new calibration kit can be ordered from your personnel only . 3Shape reseller .
  • Page 14 Let’s change dentistry together 3Shape TRIOS A/S Holmens Kanal 7 1060 Copenhagen More information at 3Shape.com Denmark...