AUX 1 24Vdc AUX1:0000 PHOTOTEST - PHOTO AUX1 AUX1 24Vdc PHOTO AUX1:0003 tst1:on 24Vac LAMP 24Vac NC NO 24Vac II° CH RADIO AUX1:0001 AUX1 PHOTOTEST - PHOTC AUX1 24Vdc PHOTC AUX1:0003 SERVICE LIGHT tst2:on AUX1:0002 24Vdc AUX1 24Vac NC NO 24Vac Relè...
Page 8
OPEN MINV:On OPEN MINV:Off OPEN OPEN MASTER SLAVE 3x0,5mm Menu BUS Menu BUS GND B A GND B A ID=0 ID=1 OPEN Close Safety Edge MOTOR Open Safety Edge bar:On (8K2/N.O. Jumper) PHOTO N.C. Open Close BAR N.C. BAR 8K2...
Page 10
Schema menu di programmazione - Menu programming layout Display OFF Diagramm Programmiermenü - Menu de programmation Menú de la carta de programación - Układ menu programowania Power ON Firmware Ver. (3s) v1. 0 0 8888 Diagnostic tped IBCA fsto fstc sldo sldc tsmo...
Page 11
RADI PUSH PUSH n TX 0012 PUSH Nman 0012 3456 MACI 2 Cycle AUTO PUSH OPEN/CLOSE RE-ENTER CODE 0000 9000 9C5a conf CODE Display OFF Legenda Premere simultaneamente (+) e (-) / Press simultaneously keys (+) and (-) Premere il tasto (-) / Press key (-) / Die Taste (-) drücken Gleichzeitig (+) und (-) drücken / Presser simultanément (+) et (-) Appuyez sur la touche (-) / Presionar la tecla (-) / Wcisnąć...
Page 12
INDEX 1) DESCRIPTION AND INTENDED USE ............22 8) CP.B1524 CONTROL UNIT .................24 2) SPECIFICATIONS ..................22 8.1) WIRE DIAGRAM................24 3) PRELIMINARY CHECKS ................22 8.2) PROGRAMMING ................24 4) INSTALLATION...................23 8.2.1) TO ACCESS PROGRAMMING ........... 24 4.1) OVERALL DIMENSIONS ..............23 8.2.2) PROGRAMMING NOTES ............
Gear motor 24Vdc for heavy-duty sliding gates up to 1500 Kg for residential or industrial buildings, with built-in controller CP.B1524 We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation updated for all the Benincà...
4) INSTALLATION 4.1) OVERALL DIMENSIONS Dimensions of the foundation plate are shown in Fig. 2. IMPORTANT: It is essential to keep the distance from the rack (40 mm), in order to position and remove the actuator once the rack is fitted to the gate leaf. The types of fittings of the foundation plate are mainly the following: 4.2) INSTALLATION WITH OPTIONAL BULL.PI RAISED BEDPLATE The BULL.PI accessory that facilitates quick fixing on existing concrete floor, is available on request.
8) CP.B1524 CONTROL UNIT 8.1) WIRE DIAGRAM Wire connections shown in Fig. 16 are described hereunder: SA.24V L-N-GND Power supply Mains input 100÷250Vac 50/60Hz Output 24Vdc Controller CP.1524 power supply output 24 Vdc BAT-BAT Batteries Clamp input for connection of back-up batteries (accessory). CP.B 1524 TERMINAL BLOCK M1 24Vdc input for powering the CP.B1524.In case of use of the SUN SYSTEM it is necessary to connect...
Page 16
8.3) TESTING - Check that the safety devices work correctly. - Check the opening/closing forces at the points set out in EN 12445 with an appropriate instrument. - If the forces are greater, install a safety device compliant with EN12978 (e.g. safety sensitive edge) and repeat the measurements. - Check the correct setup of the operation logic and that the manual release works properly.
Page 17
8.4.2) LOGICS ( MENU FUNZIONE MEMO ON-OFF-(Default) Enables or disables automatic closing On: automatic closing enabled (ON) Off: automatic closing disabled Enables or disables condominium function. On: condominium function enabled. The step-by-step impulse or transmitter impulse has no (OFF) effect during the opening phase. Off: condominium function disabled.
Page 18
The opening direction of the motor is selected: minv On: Right side motor mount (OFF) Off: Left side motor mount (fig.19) Enables or disables remote radiotransmitters learning, as indicated in the paragraph “Remote transmitters learning”. (ON) On: Remote learning enabled. Off: Remote learning not enabled.
8.4.8) PASSWORD (CODE) It allows to type in an access protection code to the programming of the control unit. A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F. The default value is 0000 (four zeros) and shows the absence of a protection code. While typing in the code, this operation can be cancelled at any moment by pressing keys + and –...
8.9) DIAGNOSTICS LED 1 : Presence of mains voltage LED 2 : Control unit CP.B1524 correctly powered To each input is associated a line of the LCD screen which in case of activation it turns on according to the following diagram. The N.C.
BULL 1524 USER’S HANDBOOK SAFETY MEASURES • Do not stand within the gate movement area. • Children must not play with controls and near the gate. • In the event of malfunctions, do not attempt to repair the failure but contact the specialised personnel.