Intruder alarm system
Emergency keys
In order to call for a help (the premises must be secured by CMS) press at once two specific keys and hold
them pressed down at least 1 second. When emergency alarm occurs, siren starts to sound and alarm
message will be shown on the keypad display.
Fire alarm
Medical alarm –
Panic alarm
Ways of disarming
Disarming can be done by two ways:
activated with the key
necessary to unmark the partitions, which will be disarmed (unmark the partitions by pressing
or select partitions by pressing
activated by entering PIN code,
Disarming by PIN code, when entering the premise
After opening the door, which are protected, the system begins to count the entry delay. During this time it is
necessary to enter PIN code. All partitions, which are controlled by user, will be disarmed.
Partial disarming
Partial disarming is useful when part of partitions should be disarmed. This kind of arming is available in
house with garage. The house partitions are disarmed, the garage partition remains armed.
, [Disarming],
10-26
+25°C
ARMED
ARMED
1st Floor
2 nd Floor
Garage
Press
key.
Alarm clearing
If an alarm has occured, on the display appears message "Alarm!!!" with an explanation, what reason
10-26
+25°C
01:44
caused it. Key
Alarm!!!
Alarm!!!
Door
CMS or to the user. There are 2 ways to clear alarm and turn off
1 way – by pressing the
After the alarm clearing action is performed the siren stops sound
the system status remains the same as was before alarm. If the system has smoke detector and alarm was
caused by smoke, which was raised by domestic reasons, the system will start alarm, nevertheless it was
armed or disarmed. The only way to clear alarm is possible by bypassing of smoke detector (see 2 page,
"Bypassing zone ).
2 way – by entering the PIN code.
After the alarm clearing action is performed the siren stops to sound,
off
, the system will be disarmed if it was armed before entering PIN code. When all partitions, which are
controlled by User, are disarmed, it's not recommended to use PIN for alarm clearing, because is possible
casual arming.
Event log review
All events, which are concerned with protected premises and status of the system, are stored in the Event
Log. The events are listed in chronological order, the used can choose to review Alarm Events, Trouble
Events, Control Events or All Events. Event log review:
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
Use
,
+
–
.
1 1 1 1
A A A A
+
.
4
4
4
4
B
B
B
B
!
!
!
!
BY
BY
BY
BY
!
!
!
!
GHI
GHI
GHI
GHI
+
–
.
7
7
7
7
C C C C
PQRS
PQRS
PQRS
PQRS
, user has possibility to disarm all or selected partitions. For partial disarming it's
...
,
,
4
4
4
4
1 1 1 1
!
!
!
!
ENT
ENT
ENT
ENT
PIN:
PIN:
PIN:
PIN:
GHI
GHI
GHI
GHI
01:44
Disarming
Disarming
Full system
Full system
Press [ENT] to disarm
Press [1]..[4] to select part.
For partial disarming press
keys.
backlight starts to blink red, the siren starts to sound and report about alarm is sending to
CLR
CLR
CLR
CLR
key and entering the PIN code:
CLR
CLR
CLR
CLR
"
, [Event Log]
, [Alarm Events]
ENT
ENT
ENT
ENT
, [Event Log]
,
[Trouble Events]
ENT
ENT
ENT
ENT
keys for navigation on the log.
with special key
,
keys and unmark/mark by pressing
all partitions, which are controlled by user, will be disarmed.
Partitions
1
1st Floor
2
2 nd Floor
3
Garage
...
Using
...
4
4
4
4
1 1 1 1
!
!
!
!
1 1 1 1
GHI
GHI
GHI
GHI
partitions which have to be disarmed.
Press
key to confirm the decision.
ENT
ENT
ENT
ENT
,
;
ENT
ENT
ENT
ENT
PIN:
PIN:
PIN:
PIN:
,
.
ENT
ENT
ENT
ENT
PIN:
PIN:
PIN:
PIN:
or by entering PIN code When disarming is
, or
keys). When disarming is
# # # #
Disarming
Disarming
keys unmark all
4
4
4
4
!
!
!
!
GHI
GHI
GHI
GHI
key:
CLR
CLR
CLR
CLR
.
PIN:
PIN:
PIN:
PIN:
,the
key backlight binking red goes off,
CLR
CLR
CLR
CLR
the
key backlight binking red goes
CLR
CLR
CLR
CLR
KM24, KM24A keypad
KM24, KM24A keypad
Short user manual
.
...
keys
4
4
4
4
1 1 1 1
!
!
!
!
GHI
GHI
GHI
GHI
****
Enter PIN
Enter PIN.
3
Need help?
Do you have a question about the KM24 and is the answer not in the manual?
Questions and answers