7

Mechanical settings and final installation

7.1

Adjusting the mechanical end stops

7.1.1

Aligning outer tube

5817,0011EN / Version 04
Mechanical settings and final installation
The attachment for the locking element at the outer tube must be
approximately centrally aligned in the direction of the home
position. The home position is the resting position of the locking
element.
1.
Remove the cover disc with the O-ring.
2.
Turn the outer tube so that the cut-out in the top cover disc is
about centred above the stop screw.
Fig. 15: Alignment of stop screw
1
Outer tube
2
Stop screw
3
Cut-out