Table of Contents

Advertisement

Quick Links

Operating Instructions
Swing Door
MPS-122
Doc-ID: 5817,0011EN
Version: 04

Advertisement

Table of Contents
loading

Summary of Contents for Magnetic Autocontrol MPS-122

  • Page 1 Operating Instructions Swing Door MPS-122 Doc-ID: 5817,0011EN Version: 04...
  • Page 2 Translation of the original operating instructions MAGNETIC Autocontrol GmbH Grienmatt 20 79650 Schopfheim Germany Tel.: +49 (0) 7622 695 5 Fax.: +49 (0)7622 695 602 E-Mail: info@ac-magnetic.com Internet: www.ac-magnetic.com 5817,0011EN / Version 04...
  • Page 3: Table Of Contents

    Requirements ..........14 Personal protective equipment ........15 Occupational safety and special dangers ....15 2.6.1 Danger pictograms on the pedestrian barrier MPS-122 ....15 2.6.2 Hazard notes and occupational safety ..16 Technical data ..............19 Dimensions ..............19 3.1.1...
  • Page 4 Swing Door MPS-122 Contents Mounting the swing door ..........29 5.4.1 Design ............29 5.4.2 Mounting the swing door on the foundation 30 Electrical connection ............33 Safety ................33 Installing electrical protective devices ......34 Performing electrical connections ....... 35 Connecting control lines to MBC-111 ......
  • Page 5 Swing Door MPS-122 Contents 10.2 Connecting laptop to control device MB-111 ....58 10.3 Using the MPS-Diag programme ......... 59 10.4 Function and parameter settings ......... 60 10.4.1 Version left / right ......... 60 10.4.2 Brake activated / not activated ..... 61 10.4.3...
  • Page 6 Swing Door MPS-122 5817,0011EN / Version 04...
  • Page 7: General

    General Information regarding the operating instructions These operating instructions provide important information on how to deal with the MAGNETIC swing door MPS-122. Prerequisite for safe working is the observance of all specified safety notes and instructions. In addition, the local accident prevention regulations valid at the pedestrian barrier's area of application and general safety regulations have to be complied with.
  • Page 8: Pictogram Explanation

    Swing Door MPS-122 General Pictogram explanation Warning notes Warning notes are characterised by pictograms in these operating instructions. The warning notes are followed by signal words expressing the scale of the hazard. It is absolutely essential to observe the notes and to proceed with caution in order to prevent accidents as well as bodily injuries and property damage.
  • Page 9: Limitation Of Liability

    Swing Door MPS-122 General Limitation of liability All specifications and notes in these operating instructions were compiled with consideration to the valid standards and regulations, the state of the art as well as to our long-standing knowledge and experience. The manufacturer is not liable for damage caused by: ...
  • Page 10: Scope Of Delivery

    Swing Door MPS-122 General Scope of delivery The scope of delivery comprises: 1 x Swing door with integrated drive and integrated  control units MBC and MMC  1 x Locking element  1 x USB-extension  1 x Drilling jig ...
  • Page 11: Customer Service

    Swing Door MPS-122 General Customer service Your vendor is available to you for technical information For the address, see invoice, delivery note or the reverse of these instructions. NOTE! In order to enable fast handling note the data of the type plate such as type code, serial number, etc.
  • Page 12: Safety

    Swing Door MPS-122 Safety Safety Intended use The MAGNETIC pedestrian barrier MPS is intended exclusively for managing the admission in to areas with restricted access. In general, the swing door is integrated in the fence and gate systems. The pedestrian barrier is intended for passage of persons who can pass the pedestrian barrier safely, quickly and without help.
  • Page 13: Operator's Responsibility

    Swing Door MPS-122 Safety Operator's Responsibility The operator must comply with the statutory obligations regarding work safety. In addition to the work safety notes in these operating instructions, the safety, accident prevention and environmental provisions applicable for the area the pedestrian barrier is used in must be complied with.
  • Page 14: Specialists And Operating Personnel

    Swing Door MPS-122 Safety Specialists and operating personnel 2.4.1 Requirements WARNING Inadequate qualification! Improper handling can lead to considerable bodily injuries and property damage. – Activities musst only carried out by the individuals designated for that purpose. The operating instructions specify the following qualification requirements for the different fields of activity: ...
  • Page 15: Personal Protective Equipment

    2.6.1 Danger pictograms on the pedestrian barrier MPS-122 The relevant dangerous areas on the pedestrian barriers can be identified by the following pictograms:...
  • Page 16: Hazard Notes And Occupational Safety

    Swing Door MPS-122 Safety 2.6.2 Hazard notes and occupational safety For your own safety and for the protection of the pedestrian barrier, the following information must be observed and complied with: Electric voltage DANGER Mortal danger by electric voltage! Touching live parts can be lethal.
  • Page 17 Swing Door MPS-122 Safety Improper transport WARNING Danger by falling down or tilting of a pedestrian barrier! The weight of the pedestrian barrier of heavy parts of it can seriously injure a person and cause serious crushing! – Have all transport work performed by specialists only.
  • Page 18 Swing Door MPS-122 Safety Inadmissible operation WARNING Inadmissible operation! An inadmissible operation can cause severe injuries. – Before operating the pedestrian barriers check all electrical and mechanical functions. Sharp edges and spiky corners CAUTION Sharp edges and spiky corners! Sharp edges and spiky corners can cause skin abrasions and cuts.
  • Page 19: Technical Data

    Swing Door MPS-122 Technical data Technical data Dimensions 3.1.1 Swing door in bracket version ∅ 159 Fig. 1: Dimensions for swing door in bracket version Safety distances to avoid crushing Total width Bracket length, Standard: 1090 mm, max. 1800 mm...
  • Page 20: Swing Door In Wing Version

    Swing Door MPS-122 Technical data 3.1.2 Swing door in wing version ∅ 159 Fig. 2: Dimensions for swing door in wing version Safety distances to avoid crushing Floor distance: 200 mm at wing height 800 mm, 170 mm at wing heights 1030 mm and 1330 mm...
  • Page 21: Operating Conditions

    Swing Door MPS-122 Technical data Operating conditions Designation Unit MPS-122 Ambient temperature range °C –25 to +45 Storage temperature range °C –30 to +70 Relative humidity % r.F max. 95 %, non-condensing Protection class – IP 44 Table 2: Operating conditions...
  • Page 22: Design And Function

    Swing Door MPS-122 Design and function Design and function Design Fig. 3: Design MPS Countersunk screw M6 x16 Cover Isolation sleeve Threaded pin Top cover disc Locking element in bracket version O-Ring Locking element in wing version Countersunk screws M8 x 20...
  • Page 23: Definition Left And Right Swing Door

    Swing Door MPS-122 Design and function Definition left and right swing door Left version Right version Mechanical stop Mechanical stop End position right End position left End position right End position left Homing Homing Home position Home position Fig. 4: Version "Left swing door"...
  • Page 24: Transport, Mounting And Installation

    Swing Door MPS-122 Transport, mounting and installation Transport, mounting and installation Safety General WARNING Inappropriate mounting and installation! Inappropriate mounting and installation can cause severe injuries! – Only qualified personnel, authorised by the operator and instructed appropriately, may carry out installation tasks.
  • Page 25 Swing Door MPS-122 Transport, mounting and installation Improper transport NOTICE Damage to the pedestrian barrier or other objects! Substantial material damage can result from improper transport. – Have all transport work performed by specialists only. – When unloading the packages and during in- plant transportation always proceed with greatest care and caution.
  • Page 26: Requirements For Mounting And Installation

    Swing Door MPS-122 Transport, mounting and installation Requirements for mounting and installation The following steps are to be completed prior to mounting and installation: Laying the foundation.   Installing the empty conduits. Foundation and empty conduits Foundation The foundation must meet the following requirements: →...
  • Page 27: Foundation Plan, Fixing And Drilling Plan

    Swing Door MPS-122 Transport, mounting and installation 5.3.1 Foundation plan, fixing and drilling plan Æ 159 Fig. 6: Foundation plan and fixing Recessed head screw M8 x 80 Spring washer Disc Tie anchor with inner thread M8 Empty conduits Frost depth: at least 800 mm...
  • Page 28 Swing Door MPS-122 Transport, mounting and installation Fig. 7: Drilling plan Drilling hole: Diameter 14.3, drilling depth: 90 mm Area for conduits Alignment of edge profile (opening) and locking element (home position) 5817,0011EN / Version 04...
  • Page 29: Mounting The Swing Door

    Swing Door MPS-122 Transport, mounting and installation Mounting the swing door 5.4.1 Design Fig. 8: Design MPS Countersunk screw M6 x16 Cover Isolation sleeve Threaded pin Top cover disc Locking element in bracket version O-Ring Locking element in wing version...
  • Page 30: Mounting The Swing Door On The Foundation

    Swing Door MPS-122 Transport, mounting and installation 5.4.2 Mounting the swing door on the foundation The foundation has cured. Prerequisites   The conduits have been placed.  The locking element is not installed yet.  Use enclosed attachment material. The swing door is fastened on the foundation with 3 tie anchors.
  • Page 31 Swing Door MPS-122 Transport, mounting and installation Loosen the 4 countersunk screws M8 and remove them. Fig. 11: Remove countersunk screws Pull out outer tube and remove it. Loosen screws and remove cover. Fig. 12: Left: Outer tube, right: Cover Setting bores.
  • Page 32 Swing Door MPS-122 Transport, mounting and installation Put the edge profile into the intended location. Insert the supply lines from below. Fig. 13: Attach edge profile Edge profile Screws M8 x 80, spring washer, washer (each 3 x) 10. Attach edge profile on the foundation with 3 screws, spring washers and washers.
  • Page 33: Electrical Connection

    Swing Door MPS-122 Electrical connection Electrical connection Safety → See also safety notes on page 15, chapter 2.6 "Occupational safety and special dangers". Electric voltage DANGER Mortal danger by electric voltage! Touching live parts can be lethal. Damage to the insulation or to individual components can be lethal.
  • Page 34: Installing Electrical Protective Devices

    Swing Door MPS-122 Electrical connection Electromagnetic interference NOTICE Electromagnetic interferences may cause malfunctions of the pedestrian barrier or adjacent devices! The pedestrian barrier is approved for industrial use. Operation in other electro-magnetic environmental conditions may cause interferences or malfunctions. – Place control lines and mains cables into separate conduits –...
  • Page 35: Performing Electrical Connections

    Swing Door MPS-122 Electrical connection Performing electrical connections NOTE! The wire cross-section of the mains cable must be between 1.5 and 4 mm . Observe national provisions on line length and associated line cross- section. Prerequisites  The locking element is not installed yet.
  • Page 36 Swing Door MPS-122 Electrical connection Connect control lines to the MBC-111. → See page 37, chapter 6.4. Switch on swing door via 2-pin main switch. Check functions. → See page 44, chapter 8. Install cover. 10. Install outer tube. 11. Install the cover disc with the O-ring.
  • Page 37: Connecting Control Lines To Mbc-111

    Swing Door MPS-122 Electrical connection Connecting control lines to MBC-111 The control and feedback lines are connected at the control unit MBC-111. → See included circuit diagram. 6.4.1 Digital inputs  all inputs are insulated by opto couplers  Input voltage 24V ±10% ...
  • Page 38: Relay Outputs

    Swing Door MPS-122 Electrical connection 6.4.2 Relay outputs  Isolated relay contacts, wired in groups Switched voltage 5 – 48V   Switched current 10 mA – 1 A Relay output Function Description Global error and alarm When certain errors occur, a continuous signal is given at output (voltage outage) this output;...
  • Page 39: Mechanical Settings And Final Installation

    Swing Door MPS-122 Mechanical settings and final installation Mechanical settings and final installation Adjusting the mechanical end stops 7.1.1 Aligning outer tube The attachment for the locking element at the outer tube must be approximately centrally aligned in the direction of the home position.
  • Page 40: Adjusting The Mechanical End Stops

    Swing Door MPS-122 Mechanical settings and final installation 7.1.2 Adjusting the mechanical end stops Right end stop Turn outer tube to the right until the stop screw touches the right end stop. Loosen the screw of the right end stop and move it until the end stop is about 92°...
  • Page 41: Mounting Locking Element

    Swing Door MPS-122 Mechanical settings and final installation Mounting locking element Danger of crushing CAUTION Danger of crushing! While the swing door is supplied with voltage, control commands can move the locking element. If these movements are made unexpectedly, they may cause crushing.
  • Page 42: Mounting Wings

    Swing Door MPS-122 Mechanical settings and final installation 7.2.2 Mounting wings NOTICE Risk of breakage! Mounting the glass wing without the rubber inserts may cause the glass wing to break. In this case, the glass wing is excluded from warranty.
  • Page 43 Swing Door MPS-122 Mechanical settings and final installation Put on the rubber inserts and holder halves. Tighten the screws M6. Secure the screws with Loctite. 5817,0011EN / Version 04...
  • Page 44: Commissioning And Settings

    Swing Door MPS-122 Commissioning and settings Commissioning and settings Safety Inappropriate commissioning! WARNING Inappropriate commissioning! Inappropriate commissioning can cause severe or lethal injuries. – Commissioning and settings must be performed by specialists only. – Prior to start of works ensure that the outer tube is correctly mounted.
  • Page 45: Switching The Swing Door On And Off

    Swing Door MPS-122 Commissioning and settings Personal protective equipment The following must be worn during comissioning:  Work clothes  Protective gloves  Safety shoes. Switching the swing door on and off Fig. 20: Switching the swing door on and off 2-pin main switch Remove the cover disc with the O-ring.
  • Page 46: Initial Commissioning

    Swing Door MPS-122 Commissioning and settings Initial commissioning Free movement path Ensure that the swing door can take up operation unhindered. The movement path of the locking element must be free. Initial commissioning Switch on power supply. If required, switch on the locking element via the 2-pin main switch.
  • Page 47: Setting The Home Position And Hold-Open Time Via Button

    Swing Door MPS-122 Commissioning and settings Setting the home position and hold-open time via button Danger of crushing CAUTION Danger of crushing! While the swing door is supplied with voltage, control commands can move the locking element. If these movements are made unexpectedly, they may cause crushing.
  • Page 48: Setting The Hold-Open Time

    Swing Door MPS-122 Commissioning and settings Swivel the locking element to the desired home position. Confirm the position by pushing the button again within the next 10 seconds. The buzzer confirms the new homing position with a continuous signal of 2 second.
  • Page 49 Swing Door MPS-122 Commissioning and settings Push the button to set the desired hold-open time. One push corresponds to one second. Examples: Push the button once for a hold-open time of one second. Push the button 25 times for the maximum hold-open time of 25 seconds.
  • Page 50: Function Description

    Swing Door MPS-122 Function description Function description Power-off state When there is no voltage, the motor is powered down. It is unlocked. The swing doors can be turned freely. Start-up routine After switching on the operation voltage, the reset version set is checked first.
  • Page 51: Regular Movement Process

    Swing Door MPS-122 Function description Left version Right version Mechanical stop Mechanical stop End position left End position right End position left End position right Homing Homing Home position Home position Fig. 22: Homing at a left swing door Fig. 23: Homing at a right swing door...
  • Page 52: Special Cases Within Motion Sequence

    Swing Door MPS-122 Function description Special cases within motion sequence 9.5.1 Obstacle recognition during the movement The behaviour can be set via the parameter "Stalled behaviour (Behaviour when obstruction detected)". → See page 62, chapter 10.4.5. The locking element can be stopped in mid-movement, e.g. when a user does not continue on or a luggage piece is caught.
  • Page 53: Attempted Vandalism

    Swing Door MPS-122 Function description 9.5.3 Attempted vandalism The behaviour can be set via the parameter "Brake options". → See page 61, chapter 10.4.2. Option "Brake on if vandalism" is Once an attempt is made to move the locking element from the activated home position, the brake is activated.
  • Page 54: 10 Setting Swing Door Parameters - "Mps-Diag

    Setting swing door parameters – "MPS-Diag" 10 Setting swing door parameters – "MPS-Diag" The swing door MPS-122 is configured ex works so that it can be commissioned without additional programing for applications with an opening angle of 2 x 90°.
  • Page 55: Driver Installation Under Windows 7

    Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.1 Driver installation under Windows 7 To establish a connection with your swing door MPS using the programme "MPS-Diag", you need to install the necessary drivers and enter the port number in the programme "MPS-Diag".
  • Page 56: Manual Driver Installation

    Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Use included driver If the installation of the driver by plugging in the USB cable does not work automatically, you need to install the driver subsequently. Start setup of the programme "MPS-Diag".
  • Page 57: Entering The Port Number In The Programme "Mps-Diag

    Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Click the button "Continue". The driver is installed. After successful installation, the message "The driver software was installed successfully" will be displayed. Use the "Device Manager" to determine the port number and enter it in the programme "MPS-Diag".
  • Page 58 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Failed driver installation  If installation was not successful, no port number is indicated for the connection "USB Serial Port". Fig. 26: Missing port number" if the installation has failed Choose another way of installing the driver. → See page 55, chapter 10.1.1 and page 56, chapter 10.1.2.
  • Page 59 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Fig. 27: Connect the laptop to the control unit MBC-111. 10.3 Using the MPS-Diag programme Install the programme "MPS-Diag" on a laptop or computer Start the included programme "MPS-Diag" via Setupxxx.exe and execute the instructions of the installation routine.
  • Page 60 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.4 Function and parameter settings Function and parameter settings are made through the Windows programme MPS-Diag. The following functions can be set:  Design left / right  Brake activated / not activated in the three positions, in case of vandalism or when pressed in the wrong direction ...
  • Page 61 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Fig. 29: Explanation on version "Right" and "Left", here the directions for the right swing door are presented 10.4.2 Brake activated / not activated This option is used to inform the control if the brake is to be activated when one of the three positions is reached, in case of vandalism or when pressed in the wrong direction.
  • Page 62 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.4.3 Select size of the locking element Choose the length of the locking bracket via the selection point. Fig. 31: Select length of the locking bracket Always select the setting "more than 1.3 m" for swing doors in the wing version.
  • Page 63 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.4.6 Set hold-open time The "hold-open time" parameter is used to set the hold-open time between 0 and 25 seconds in steps of 100 ms. Entering 50 means 5 seconds. Fig. 34: Set hold-open time 10.4.7...
  • Page 64 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.4.9 Teaching the three possible positions The MPS is delivered with 2 x 90° opening angles by default. However, the three positions can be changed independently. For this, there is an input mask in MPS-Diag.
  • Page 65 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Adjust "home position". Fig. :40 Adjust home position Adjust "left position". Fig. 41: Adjust "left position" Adjust "right position". Fig. 42: Adjust "right position" 5817,0011EN / Version 04...
  • Page 66 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Confirm changes by clicking the button "Close". The MBC control is restarted. Fig. :43 Reset control MBC 10.4.10 Reset all parameters to factory settings This option can be used to restore the factory settings for all parameters.
  • Page 67 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Safety confirmation "All parameters are reset to factory settings. Do you want to continue?" Fig. 46: Safety confirmation  Clicking "Yes" resets all parameters to factory settings.  Clicking "No" cancels the process.
  • Page 68 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" A dialogue window appears. The dialogue window display depends on the control type. If communication with the control is impossible, the MBC field will show a question mark. Fig. 48: Menu "Firmware update" (here: no communication)
  • Page 69 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.5.1 Firmware download using a ".mcp file" Fig. 49: Button "Download Firmware" After clicking the button "Download firmware”, the programme status bar shows the download progress. Fig. 50: Download progress When the download is completed, perform voltage reset.
  • Page 70 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" Fig. 52: Control selection The dialogue "Confirmation" is displayed. Fig. 53: Dialoge "Confirmation" Observe the dialogue instructions precisely. When you have performed all steps, click the "OK" button. When the connection to the bootloader is established, the download will start.
  • Page 71 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.6 Download between MBC-111 and MMC-120 Each time the MBC-111B is booted after voltage is switched on again, software verification is performed between the MBC-111 and the connected motor control device MMC-120. It verifies that the motor control device has the right software and the right software version for the MBC-111 application software.
  • Page 72 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.7 Reading errors Reading the error codes right at the MBC-111 or MMC-120 is only possible after disassembly after removing the outer tube with the locking element. Therefore, the programme MPS-Diag offers the possibility of reading errors from the MBC-111 and MMC-120 controls through the serial interface.
  • Page 73 Swing Door MPS-122 Setting swing door parameters – "MPS-Diag" 10.8 Status request Reading the conditions of the in- and outputs right at the MBC-111 is only possible after disassembly after removing the outer tube with the locking element. Therefore, the programme MPS-Diag offers the possibility of reading the status of the in- and outputs through the serial interface.
  • Page 74 Swing Door MPS-122 Cleaning and maintenance 11 Cleaning and maintenance 11.1 Safety → See also safety notes on page 15, chapter 2.6 "Occupational safety and special dangers". DANGER Electric voltage Mortal danger by electric voltage! Touching live parts can be lethal.
  • Page 75 Swing Door MPS-122 Cleaning and maintenance Danger of crushing CAUTION Danger of crushing! While the swing door is supplied with voltage, control commands can move the locking element. If these movements are made unexpectedly, they may cause crushing. – If possible, disconnect the swing door from the voltage.
  • Page 76 Swing Door MPS-122 Cleaning and maintenance 11.2 Cleaning Aggressive cleaning aids and NOTICE substances Unit damage possible! Aggressive cleaning agents and substances can damage or destroy electrical cables and components. – Do not use cleaning agents with aggressive ingredients. Carrying out cleaning work: Switch off power supply and secure against restarting.
  • Page 77 Swing Door MPS-122 Cleaning and maintenance 11.3 Maintenance schedule The following describes the maintenance work that is necessary for optimal, trouble-free operation. Maintenance intervals must be observed. If increased wear of individual components or functional groups is revealed during regular inspections, the operator must reduce the required maintenance intervals on the basis of the actual signs of wear.
  • Page 78 Swing Door MPS-122 Malfunctions 12 Malfunctions 12.1 Safety This chapter describes possible causes of malfunctions and trouble shooting tasks. Contact the manufacturer in case of malfunctions that cannot be repaired by means of the following information. (For service address, refer to page 2)
  • Page 79 Swing Door MPS-122 Malfunctions Inappropriate troubleshooting! WARNING Inappropriate troubleshooting! Inappropriate troubleshooting can cause severe or lethal injuries. – All troubleshooting work must be performed by specialists or electronics specialists. – Prior to work, ensure that there is sufficient assembly space.
  • Page 80 Swing Door MPS-122 Malfunctions 12.2 Error codes on the logic controller MBC-111 NOTE! Additionally, dispose of the programme "MPS Diag" for further diagnostics. Here you can read out the → errors via the serial interface. See page 72, chapter 10.7 Display error codes The MBC-111 has an LED display for diagnosis purposes.
  • Page 81 Swing Door MPS-122 Malfunctions Error code Fault description Automatic reset Error when initialising CAN protocol stack Error when initialising CAN bus CAN servo address fault Error download of controller parameters for the MMC-120 Reserved Error I²C-EEPROM Software fault 70 to 7F...
  • Page 82 Swing Door MPS-122 Malfunctions 12.3 CAN bus addressing and termination The MBC-111 logic controller and the MMC-120 motor controller exchange data via a CAN bus line. The MMC-120 controllers must have a fixed CAN address assigned to it. Additionally, a termination resistor must be activated at both ends of the bus to prevent interference.
  • Page 83 Swing Door MPS-122 Spare parts 13 Spare parts Incorrect or defective spare parts WARNING Incorrect or defective spare parts! Incorrect or defective spare parts can result in damage, malfunctions or total failure and also impair safety. – Use only the manufacturer's original spare parts.
  • Page 84 Swing Door MPS-122 Decommissioning, disassembly and disposal 14 Decommissioning, disassembly and disposal A pedestrian barrier that is no longer usable should not be recycled as a complete unit, but disassembled into individual components and recycled according to material types. Non-recyclable materials have to be disposed of in an environmental-friendly manner.
  • Page 86 Swing Door MPS-122 Appendix 16 Appendix 16.1 Electric circuit diagram The electric circuit diagram is supplied as a separate document. 5817,0011EN / Version 04...
  • Page 87 Swing Door MPS-122 Index Index Function description ..........50 Function settings ..........60 Adjustment End stops ............40 General ..............7 Bracket ............22, 29 Mounting ............41 Hazard notes ............16 Bracket version ........... 19 Homing ..............50 Button Hold-open time ..........
  • Page 88 Swing Door MPS-122 Index Pictogram explanation ......... 8 Specialised staff ..........14 Programme MPS-Diag ........54 Specialists Requirements ..........14 Swing door Relay outputs ............. 38 Bracket version ..........19 Right swing door ..........23 Wing version ........... 20 Switching off ............45 Switching on ............
  • Page 89 Swing Door MPS-122 5817,0011EN / Version 04...
  • Page 90 MAGNETIC Autocontrol GmbH Grienmatt 20 79650 Schopfheim Germany Tel.: +49 7622 695 5 Fax: +49 7622 695 602 e-mail: info@ac-magnetic.com F10042001...

Table of Contents