Electric Heater Function And Troubleshooting; Description Of Electric Heater Components - Bryant SM03-4 Service Manual

Residential fan coil units
Table of Contents

Advertisement

BLOWN
DIODE
(b)
BLOWN
DIODE
(a)
ELECTRIC HEATER FUNCTION AND
TROUBLESHOOTING
This section describes KFA, KFB, KFC, and KFD series electric
heaters in exclusion of Smart Heat by examining the functional
operation of these heaters.
I. DESCRIPTION OF ELECTRIC HEATER
COMPONENTS
A. Limit Switch
The limit switch is a temperature-sensitive control whose function
is to prevent system from overheating in abnormal conditions. The
temperature settings often vary from heater to heater due to
variations in airflow patterns and element radiant heat conditions.
The devices are sized to remain on-line under heat pump condi-
tions (115°F air off coil) and minimum CFM, but trip to prevent
outlet air conditions above 200°F or excessive component or duct
temperatures.
2FC-1
C
HK61GA001A
3
2
1
6
5
4
9
8
7
12
11
10
TRANSFORMER
AC LINE
T1
T2
T3
L2
COMMON
DUMMY
L1
240 VAC
Fig. 14—Control Board Noting Diodes
—19—
AUX1
24VDC
AUX2
F4
RELAY
F3
DUMMY
F2
DUMMY
EAC2
FAN
F1
COMMON
EAC1
240 VAC
The device itself consists of a bimetallic disc, which when
overheated "snaps through" to open a normally-closed high-
voltage, high-current switch. When system temperatures cool
sufficiently, the switch will automatically reset to its closed
position. Normal failure mode for this switch is open.
If a limit switch has been determined to be defective, NEVER
BYPASS THE LIMIT SWITCH. When replacing limit switch,
ensure that it is replaced with a limit switch of identical opening
temperature and closing differential. Limits switches are typically
color coded to identify their range.
B. KFA and KFB Sequencer
The sequencer is essentially a thermally activated time-delay relay
normally activated by low-voltage control signals from thermostat.
The typical sequencer is a 1- or 2-pole normally-open device
which energizes within 10 to 30 sec after application of control
signal and de-energizes 60 to 90 sec after control signal is
removed.