SYSTEM CHECKS
1. Conceal the tubing where possible.
2. Ensure the drain tube slopes downward along its entire
length.
3. Ensure all tubing and connections are properly insulated.
4. Fasten tubes to the outside wall, when possible.
5. Seal the hole through which the cables and tubing pass.
INDOOR UNIT
1. Do all remote control buttons function properly?
2. Do the display panel lights work properly?
3. Does the air deflection louver function properly?
4. Does the drain work?

TROUBLESHOOTING

For ease of service, the systems are equipped with diagnostic code
display LEDs on both the indoor and outdoor units. The indoor
diagnostic display is a combination of flashing LEDs on the
display panel or the front of the unit.
INDOOR UNIT DIAGNOSTIC GUIDES
OPERATION LAMP
1 time
2 times
3 times
4 times
5 times
6 times
7 times
1 time
2 times
3 times
4 times
5 times
6 times
1 time
2 times
3 times
5 times
For additional diagnostic information, refer to the Service Manual
E2017 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Table 8—ID Units Error Code Display
TIMER LAMP
DISPLAY
X
E0
X
E1
X
E2
X
E3
X
E4
X
E5
X
EC
O
F0
O
F1
O
F2
O
F3
O
F4
O
F5
P0
P1
P2
P4
O (on − light)
Explain Following Items To Customer
(with the aid of the Owner's Manual):
1. How to turn air conditioner on and off; selecting
COOLING, HEATING and other operating modes; setting
a desired temperature; setting the timer to automatically start
and stop the air conditioner operation; and all other features
of the remote control and display panel.
2. How to remove and clean the air filter.
3. How to set air deflection louver.
4. Explain care and maintenance.
5. Present the Owner's Manual and installation instructions to
customer.
Some indoor units display error codes specifying failure modes in
the outdoor units. If possible, always check the diagnostic codes
displayed on the indoor unit first.
The diagnostic codes displayed in the indoor and outdoor units are
listed in Table 8.
Indoor unit EEPROM parameter error
Indoor / outdoor units communication error
Zero-crossing signal detection error
Indoor fan speed is out of control
Indoor room temperature sensor T1 open circuit or short circuit
Evaporator coil temperature sensor T2 open circuit or short circuit
Refrigerant leakage detection
Overload current protection
Outdoor ambient temperature sensor T4 open circuit or short circuit
Condenser coil temperature sensor T3 open circuit or short circuit
Compressor discharge temperature sensor T5 open circuit or short circuit
Outdoor unit EEPROM parameter error
Outdoor fan speed is out of control
IPM malfunction or IGBT over-strong current protection
Over voltage or over low voltage protection
High temperature protection of the compressor top diagnosis and solution
(only for 9k,12k models)
Inverter compressor drive error
☆(flash)
X(off − light)
Edition Date: 09/17
14
LED STATUS
Catalog No. II619PB-02
Replaces: 619PB-01SI