(5) Install the air exhaust pipe
1) Fix the air exhaust pipe on the ventilation outlet assy.
by the clamp. The pipeline connected to outside of
the room must be slanted to prevent rain or
condensed water from flowing backwards.
NOTE: When the ceiling is unable to dismantle, please
set a square inspection hole of at least 450mm.
INSTALLATION OF REMOTE CONTROLLER HOLDER
INSTALLATION OF REMOTE CONTROLLER HOLDER
NOTE:
If the wall for installation is made of special material
(such as wood board, density board and etc.), suitable fixing
methods shall be adopted.
NOTE:
The place to install the remote controller shall not be
easily splashed by water. It mustn't be accessible by people
taking a bath or shower.
Choose a mounting location for the remote holder.
Drilling two holes with depth larger than 45mm on the wall by
drill with a diameter of 6mm in accordance with the position of
screw holes on the remote control holder. Installing the
expansion tube into the holes.
Placing the installation holder on the fixing hole.
Fixing the holder with screws and install it.
Installing the screw covers on the screws.
Placing the remote controller on the holder.
Remote Control
INSTALLATION OF COIN BATTERY
INSTALLATION OF COIN BATTERY
Please follow the installation diagram.
1430823-T01-A
Air Exhaust Pipe
Ventilation Outlet Assy.
Clamp
Screw
Cover
Coin Battery (CR2430)
-11-
(5)
1)
(
80mm
)
Indoors
Outdoors
45mm
Base
Slant Taper
1
1
(
~
)
100
50
450mm
6mm
Expansion Tube