Acoustic Test Report
Maverick Silens 2 Profile
Instrumentation
The following were used in the acoustic testing:
Equipment
Semi-anechoic chamber
Noise analyzer
Mechanical thermohygrograph
Condenser microphone
Condenser microphone
Condenser microphone
Condenser microphone
Results
The Maverick Silens 2 Profile was measured in seven different scenarios:
1. Unit ON, but no intensity, static
2. Full intensity, static
3. Full intensity, pan and tilt moving
4. Full intensity, pan and tilt static, all other functions moving
5. Full intensity, all functions moving
6. Total Silence Mode: full intensity, pan and tilt moving
7. Total Silence Mode: full intensity, all functions moving
The sound pressure levels are listed in the table below:
Fixture Mode
Unit ON (no intensity, static)
Full intensity (static)
Full intensity (pan/tilt moving)
Full intensity (pan/tilt static, all functions moving)
Full intensity (all functions moving)
Total Silence Mode: Full intensity (pan/tilt moving)
Total Silence Mode: Full intensity (all functions moving)
Chauvet Professional –
www.chauvetprofessional.com
©2021, Chauvet & Sons, LLC. All rights reserved.
All product specifications, measurements, and dimensions are subject to change without notice.
Type
Number
- - -
R40010
3160-A-042
R40011-2
TH603A
rd078
4189-A-021
R40011-4
4189-A-021
R40011-5
4189-A-021
R40011-6
4189-A-021
R40011-7
Calibration Period
2023.05
2021.05
2021.09
2021.05
2021.05
2021.05
2021.05
Sound Pressure Level (dB)
31.33
32.98
38.60
40.73
40.63
37.48
38.18