  • Page 1 ACOUSTIC TEST REPORT...
  • Page 2 Indoor noise: <10 dB (A) The Maverick Silens 2 Profile was placed on the floor of a semi-anechoic chamber, with four microphones (Signals 1–4) placed 1 meter away in all four directions to detect its sound pressure level. Signal 4...
  • Page 3 4189-A-021 R40011-7 2021.05 Results The Maverick Silens 2 Profile was measured in seven different scenarios: 1. Unit ON, but no intensity, static 2. Full intensity, static 3. Full intensity, pan and tilt moving 4. Full intensity, pan and tilt static, all other functions moving 5.
  • Page 4 Contact Us General Information Technical Support Chauvet World Headquarters 5200 NW 108 Ave. Sunrise, FL 33351 Voice: (844) 393-7575 Voice: (954) 577-4455 Fax: (954) 756-8015 Fax: (954) 929-5560 Email: chauvetcs@chauvetlighting.com Toll Free: (800) 762-1084 Website: www.chauvetprofessional.com Chauvet Europe Ltd Unit 1C Brookhill Road Industrial Estate Email: UKtech@chauvetlighting.eu...