Installation Of Outdoor Unit - Gree GVH24AK-K3DNC6A Service Manual

Hide thumbs Also See for GVH24AK-K3DNC6A:
Table of Contents

Advertisement

Step two: Wiring of indoor unit
1. Remove the left and right support plate. electric box is in the
left of the unit, press the screw at the electric box cover, take off
the electric box cover.
2. Take out the electric box cover, screw down the test wire of
screw,take out the test wire from the cable cross hole.
(As show in Fig.19)
screw
Fig.19
cable cross hole
3. Thread the power connection wire through the cable cross hole
from the cable cross hole.
4. Well connect the wire according to wiring diagram.(As show in
Fig.20)
5. Fix the protecting cover section of power connection wire at the
groove of wire clamp and then screw up the fixing screw to fix the
connection wire firmly.
blue
black
brown
wire clamp
connecting cable
Fig.20
Note:
Please contact the maintenance center for another connection
wire with adequate length if the present one is not long enough.
1. Correctly connect the wires.
2. Well screw up the screws fixing terminals and connection
wirings.
3. The wirings should be properly fixed.
4. Incorrect wiring connection of grounding wire may lead to
electric shock.
5. Well fix the electric box cover with sufficient screw. Improper
assembly of electric box cover may cause fire hazard or electric
shock.
6. For the air conditioner without plug, an circuit break must be
installed in the line. The circuit break should be all-pole parting
and the contact parting distance should be more than 3mm.
7. All wires of indoor unit and outdoor unit should be connected by
a professional.
8. If the length of power connection wire is insuffucient, please
contact the supplier for a new one.Avoid extending the wire by
yourself.
9. For the air conditioner with plug, the plug should be reachable
after finishing installation.
32
wiring board
test wire
wiring board
brown
blue
yellow/green
(black)
wire clamp
power cord
Step three: Installation of rear cover
1. Bind the connection pipe, connection wire and drainage pipe
together with binder.(As show in Fig.21)
● Fix some positions for convenient binding
● Do not bind too tightly.
● Leave the joint of connection pipe for leakage test.
● Knock down the sub-small hole for 24 unit when cutting the
baiting.
2. According to installation position, cut one of the baitings, thread
the packed pipe and wire through the baiting hole.(As show in
Fig.22)
3. Assemble the rear case.
connection pipe
drainage
pipe
connection
pipe
binder
drainage
pipe

8.7 Installation of Outdoor Unit

Installation dimension diagram of outdoor unit
(As show in Fig.23)
Space to the covering
Service Manual
binder
connection wire
Fig.21
connection pipe,
connection wire and
drainage pipe
rear cover
Fig.22
Fig.23
Installation and Maintenance

Advertisement

Table of Contents
loading

Table of Contents