Good Read Delay
This sets the minimum amount of time before the scanner can read another bar
code. Default = No Delay.
* No Delay
Short Delay (500 ms)
Medium Delay (1000 ms)
Long Delay (1500 ms)
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code
below, then set the delay (from 0-30,000 milliseconds) by scanning digits from
the inside back cover, then scanning Save .
User-Specified Good Read Delay
Trigger Modes
Manual/Serial Trigger
You can activate the scanner either by pressing the trigger, or using a serial
trigger command (see
Trigger Commands
on page 11-4). When in manual
trigger mode, the scanner scans until a bar code is read, or until the trigger is
released.
When in serial mode, the scanner scans until a bar code has been read or until
the deactivate command is sent. In serial mode, the scanner can also be set to
turn itself off after a specified time has elapsed (see
Read
Time-Out, which
follows).
* Manual/Serial Trigger
3800i/3800r User's Guide
3 - 3