10 Technical Data
Model
DC input ports
Number of PV input ports
Maximum module power, per port (Wdc)
Peak power MPPT voltage range (Vdc)
Start-up voltage (Vdc)
Operating voltage range (Vdc)
Maximum input voltage (Vdc)
Max. input current (Adc), per port
Max. input short circuit current (Adc), per port
AC output
Peak output power (VA)
Maximum continuous output power (VA)
Maximum continuous output current (A)
Nominal output voltage/range (V)
Nominal frequency/range (Hz)
Power factor
Output current harmonic distortion
Maximum units per 20A branch
Maximum units per 30A branch
Efficiency
Peak inverter efficiency
CEC weighted efficiency
Nominal MPPT efficiency
Night time power consumption (mW)
Mechanical Data
Ambient temperature range (°C)
Storage temperature range (°C)
Dimensions (W×H×D mm)
Weight (kg)
Enclosure rating
Cooling
Features
Communication
Monitoring
Warranty
Compliance
*Note: Voltage and frequency ranges can be extended beyond nominal if required by the utility.
Installation Manual
VDE-AR-N 4105:2018, EN50549-1:2019, VFR2019, AS 4777.2:2015, IEC/EN
D350-M1
D700-M2
1
440
440
33~48
33~48
16~60
11.5
350
700
349
696
1.68@208V
3.35@208V
1.52@240V
2.92@240V
208/183-229
240/211-264
55-65
>0.99 default 0.8 leading......0.8 lagging
<3%
9@208V
4@208V
11@240V
5@240V
14@208V
7@208V
16@240V
8@240V
96.70%
96.50%
99.80%
<50
-40 ~ +65
-40 ~ +85
182×164×29.5
250 x 170 x 28
1.75
2.60
Outdoor NEMA type 6 (IP67)
Natural convection – no fans
2.4GHz Proprietary RF(Nordic)
Power Center+Monitoring System
(Power Center+DTU is required)
12 years standard, 25 years optional
62109-1/-2, IEC/EN 61000-3-2/-3,
IEC/EN-61000-6-1/-2/-3/-4
D1500-M4
2
4
470
36~48
22
60
15
1350@208V
1500@240V
1246@208V
1438@240V
5.99@208V
6.25@240V
2@208V
2@240V
4@208V
4@240V
280 x 176 x 33
3.35
18

Advertisement