Introduction; General Information; Specifications - Ransburg RMA-303 INDIRECT Service Manual

Test stations
Hide thumbs Also See for RMA-303 INDIRECT:
Table of Contents

Advertisement

Test Stations - Introduction

INTRODUCTION

GENERAL INFORMATION

The Ransburg Applicator Performance Test Stand
was developed to assist in determining the appli-
cator's level of performance in an off-line condi-
tion. (Ensuring the applicator functions properly
after any maintenance has been performed to it
and reduces the costs associated with verifying
performance during production.) With line speeds
critical to the through-put of a facility, every uptime
minute counts to underwrite profitability. This
Test Stand device helps to ensure the applicator
performs correctly when it is put into service.
This Test Stand will verify performance of single
or dual fluid applicators, bearing air, shaping air,
brake air, turbine drive air, and fiber optic func-
tionality. As well, it checks kV and µA electrical
performance of the applicator.
The Test Stand was developed with the user and
the safety of the user in mind. The user must
become familiar with the overall function and
operation of the unit.
N O T E
> For all test station toggle switches, with the
switch lever in the "UP" position, the valve it
describes is "ON" or "actuated."
5

SPECIFICATIONS

Electrical / Physical
Air Requirements:
1-inch NPT(F) Inlet
3/4-inch ID Air Line to Stand
100 psi (6.4 bar) minimum
30 SCFM
0.3 to 0.6 Micron Filtration
Dimensions
Height:
67-inch (1702cm)
Width:
30-inch (762cm)
Length:
48-inch (1219cm)
Fluids:
Use distilled or deionized
water only for testing.
Maximum Fluid
Pressure:
80 psi (5.2 bar)
LN-9259-07.1