Test stations
Hide thumbs Also See for RMA-303 INDIRECT:
Table of Contents

Advertisement

2. Adjust the "Atom Air" control knob on the panel
until there is 50 psi flowing on the atom air gauge.
Check that the atom air pressure test gauge
shows a pressure.
1 00
1 00
3. Adjust the "Manual Fan Air" control knob on
the panel until there is 50 psi flowing on the fan
air gauge. Check that the fan air pressure test
gauge shows a pressure.
1 00
1 00
4. Turn the "Bell/Applicator" switch to "OFF"
position.
LN-9259-07.1
> Always verifty the flow meter regulator
is set at 100 psi.
5. Turn off the "Fan and Atom Air" controls.
6. Remove the test cap from the applicator.
S.A.I./ATOM
Flow Test
1. Turn on the "Water/Air" switch to the "Water"
position.
2. Turn on the pressure pot valve.
3. Turn on the"Paint Fluid Enable" switch.
S.A.O./FAN
4. Turn on the "Dump Trigger" until there is no air
in the line, then turn off.
Test Stations - Operation