Ransburg 76652-01 Service Manual

Ransburg 76652-01 Service Manual

Paint, high voltage & sci test equipment, high voltage probe, sprayability/sci meter, paint resistivity meter, deluxe kit
Hide thumbs Also See for 76652-01:

Advertisement

PAINT, HIGH VOLTAGE & SCI TEST
PAINT, HIGH VOLTAGE & SCI TEST
MODELS:
MODELS:
EQUIPMENT
EQUIPMENT
76652-01 HIGH VOLTAGE PROBE
76652-02 SPRAYABILITY/SCI METER
76652-03 PAINT RESISTIVITY METER
76652-04 DELUXE KIT
IMPORTANT: Before using this equipment,
IMPORTANT: Before using this equipment,
carefully read SAFETY PRECAUTIONS,
carefully read SAFETY PRECAUTIONS,
starting on page 1, and all instructions in
starting on page 1, and all instructions in
this manual. Keep this Service Manual for
this manual. Keep this Service Manual for
future reference.
future reference.
SERVICE MANUAL
TE-98-01.2
TE-98-01.2
(Supercedes TE-98-01.1)
Service Manual Price:
Service Manual Price:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 76652-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ransburg 76652-01

  • Page 1 PAINT, HIGH VOLTAGE & SCI TEST PAINT, HIGH VOLTAGE & SCI TEST EQUIPMENT EQUIPMENT MODELS: MODELS: 76652-01 HIGH VOLTAGE PROBE 76652-02 SPRAYABILITY/SCI METER 76652-03 PAINT RESISTIVITY METER 76652-04 DELUXE KIT IMPORTANT: Before using this equipment, IMPORTANT: Before using this equipment,...
  • Page 2 N O T E : N O T E : This manual has been changed from revision TE-98-01.1 TE-98-01.1 to revision TE-98-01.2 TE-98-01.2. Reasons for this change are noted under “Manual Change Summary” inside the back cover of this manual.
  • Page 3: Table Of Contents

    HAZARDS / SAFEGUARDS............. MULTI-FUNCTION ELECTROSTATIC METER...... SPRAYABILITY, SCI, AND RESISTANCE MEASUREMENT KIT..............PAINT RESISTANCE MEASUREMENT KIT......HIGH VOLTAGE MEASUREMENT KIT........GENERAL MAINTENANCE............LIMITED WARRANTY............... ITW RANSBURG PAINT AND SOLVENT SPECIFICATIONS..............ITW RANSBURG VISCOSITY CONVERSION CHART..VOLUMETRIC CONTENT OF HOSE OR TUBE..... TE-98-01.2...
  • Page 4: Safety Precautions

    Before operating, maintaining or servicing any The user MUST MUST read and be familiar > ITW Ransburg coating system, read and under- with the Safety Section in this manual and stand all of the technical and safety literature for the ITW Ransburg safety literature therein your ITW Ransburg products.
  • Page 5: Hazards / Safeguards

    Paint, High Voltage & SCI Test Equipment WARNING The following hazards may occur during the normal use of this equipment. Please read the following chart. A R E A A R E A HAZARD HAZARD SAFEGUARDS SAFEGUARDS Tells where hazards Tells what the hazard is.
  • Page 6: Multi-Function Electrostatic Meter

    µA: 0 to ±1999 µA kΩ: 1 to 1999 kΩ (.001 to 1.999 MΩ) MΩ: 00.1MΩ to 199.9 MΩ The ITW Ransburg Multi-Function Electrostatic GΩ: .1GΩ to 19.99 GΩ Spray Meter uses one meter to serve multi * Note: Note: For readings below 2 MΩ, more resolu- functions in electrostatic spray finishing.
  • Page 7 Paint, High Voltage & SCI Test Equipment Figure 1A: Multi-Function Meter Figure 1A: Multi-Function Meter Figure 1B: Multi-Function Meter Kit Parts Figure 1B: Multi-Function Meter Kit Parts TE-98-01.2...
  • Page 8: Sprayability, Sci, And Resistance Measurement Kit

    Since many non-conductive products must be pre-treated with a conductive solution to make them sprayable, the ITW Ransburg Multi-Func- tion Electrostatic Spray Meter is useful to moni- tor and maintain consistency in that application, once a suitable reading is determined.
  • Page 9 Paint, High Voltage & SCI Test Equipment New 76652-01 Multi-Function New 76652-01 Multi-Function 8333-00 Sprayability 8333-00 Sprayability Spray Condition Spray Condition Meter Reading Meter Reading Meter Reading Meter Reading 1 MΩ Suitable 2 MΩ Suitable 3 MΩ Suitable 4 MΩ...
  • Page 10 Target/Product Ground Set the meter dial to the MΩ scale (see Figure 3). Plug the probe with (2) alligator The Ransburg Multi-Function Meter may be clamp leads into the side of the meter. Check used to measure approximate resistance in the meter calibration by touching the metallic kΩ, MΩ...
  • Page 11 (Power Supplies) Measure and record the short circuit current from the meter. This value should be compared The Ransburg Multi-Function Meter may be to the value listed in the appropriate power sup- used to measure the short circuit current of an ply service manual.
  • Page 12 (Guns) (Guns) ranges indicated in Table 3. Consult power sup- ply and applicator manuals for readings outside The Ransburg Multi-Function Meter may be these ranges. used to measure the short circuit current of an electrostatic applicator. The short circuit current...
  • Page 13: Paint Resistance Measurement Kit

    Paint Resistivity current that is drawn to ground. current that is drawn to ground. The Ransburg Paint Resistance measurement kit using the multi-function meter is designed to provide measurement of the electrical resis- Ensure the meter's scale is properly set...
  • Page 14: High Voltage Measurement Kit

    Meter Readings Meter Readings High Voltage Measurement High Voltage Measurement Table 4 lists the ranges of paint resistivity that work best for specific Ransburg applicators. The Ransburg High Voltage measurement kit using the multi-function meter is designed to Applicator Applicator...
  • Page 15 All personnel in the hazard (booth) area All personnel in the hazard (booth) area MUST be grounded. MUST be grounded. See ITW Ransburg See ITW Ransburg bulletin, Personnel Grounding. bulletin, Personnel Grounding. These operating instructions MUST be read and...
  • Page 16: General Maintenance

    Paint, High Voltage & SCI Test Equipment Insert the cable into the high voltage tube of the power supply, inserting it far enough to make contact with the contact spring at the bottom of the tube. Turn the power supply on. Read the voltage displayed on the meter.
  • Page 17 Appropriately discard used battery. factory for repair or recalibration. N O T E N O T E ITW Ransburg recommends that the Multi- The screen will go blank when the battery Function Meter and its associated equipment needs to be replaced.
  • Page 18: Limited Warranty

    EXCLUSIONS: EXCLUSIONS: EQUIPMENT: When purchased as a complete If, in ITW Ransburg's opinion the warranty item unit, (i.e., guns, power supplies, control units, in question, or other items damaged by this part etc.), is one (1) year from date of purchase.
  • Page 19: Itw Ransburg Paint And Solvent Specifications

    Paint, High Voltage & SCI Test Equipment APPENDIX APPENDIX ITW RANSBURG PAINT AND SOLVENT SPECIFICATIONS ITW RANSBURG PAINT AND SOLVENT SPECIFICATIONS AEROBELL AEROBELL II*** II*** AEROBELL AEROBELL AEROBELL AEROBELL - 1 0 1 - 1 0 1 ® ® / EFM...
  • Page 20: Itw Ransburg Viscosity Conversion Chart

    Paint, High Voltage & SCI Test Equipment ITW RANSBURG VISCOSITY CONVERSION CHART ITW RANSBURG VISCOSITY CONVERSION CHART 1000 1100 1200 1280 1380 1475 1530 1630 1730 1850 1950 2050 2160 2270 2380 2480 2660 2900 3375 3380 4300 10.0 1000 4600 11.0...
  • Page 21 Paint, High Voltage & SCI Test Equipment ITW RANSBURG VISCOSITY CONVERSION CHART (Continued) ITW RANSBURG VISCOSITY CONVERSION CHART (Continued) 13.0 1300 6100 14.0 1400 6480 15.0 1500 7000 16.0 1600 7500 17.0 1700 8000 18.0 1800 8500 19.0 1900 9000 20.0...
  • Page 22: Volumetric Content Of Hose Or Tube

    Paint, High Voltage & SCI Test Equipment VOLUMETRIC CONTENT OF HOSE OR TUBE VOLUMETRIC CONTENT OF HOSE OR TUBE (English Units) (English Units) C r o s s C r o s s Length Length I.D. I.D. cc/ft. cc/ft. Section Section (inches) (inches)
  • Page 23 "Operation", located in the "Paint Resistance Measurement Kit" section. Revised "Safety Precautions" section. Added "Warranty Policies" section. Revised "ITW Ransburg Paint and Solvent Specifications" in the "Appendix" section. Revised "ITW Ransburg Viscosity Conversion Chart" in the "Appendix" section.
  • Page 24 Trademarks indicated with ® are registered with the United States Patent and Trademark Office by ITW Ransburg. Form No. TE-98-01.2 *ITW Ransburg Industrial Systems is an ISO 9001 compliant company registered with Factory Mutual. Litho in U.S.A. Models and specifications subject to change without notice.

This manual is also suitable for:

76652-0376652-0276652-04

Table of Contents