Test stations
Hide thumbs Also See for RMA-303 INDIRECT:
Table of Contents

Advertisement

Test Stations - Operation
W A R N I N G
> Never use solvent as a test fluid for
this device.
4. Loosen the pressure pot clamps until the lid
may be removed from the pot. Fill the pressure
pot with de-ionized or distilled water.
13
5. Close the lid, tighten the lid clamps so that the
lid is secure and no air pressure may escape.
6. Turn the "Fluid" switch to "Water" position.
7. Turn the "Fluid Air" regulator to the pressure
pot to 80 psi.
8. Make sure the dump line is secured in the buck-
et and the dump valve is in the "Open" position.
9. Turn on "Paint Fluid Enable" and cup wash
"Solvent Fluid Enable" in the Fluid Enable section.
LN-9259-07.1