Ransburg RMA-303 INDIRECT Service Manual page 7

Test stations
Hide thumbs Also See for RMA-303 INDIRECT:
Table of Contents

Advertisement

AREA
Tells where hazards
may occur.
General Use and
Maintenance
Electrical
Equipment
LN-9259-07.1
HAZARD
Tells what the hazard is.
Improper operation or mainte-
nance may create a hazard.
Personnel must be properly
trained in the use of this equip-
ment.
High voltage equipment is uti-
lized. Arcing in areas of flam-
mable or combustible materi-
als may occur. Personnel are
exposed to high voltage during
operation and maintenance.
Protection against inadvertent
arcing that may cause a fire
or explosion is lost if safety
circuits are disabled during
operation.
Frequent power supply shut-
down indicates a problem in
the system which requires
correction.
An electrical arc can ignite
coating materials and cause
a fire or explosion.
SAFEGUARDS
Tells how to avoid the hazard.
Personnel must be given training in accordance
with the requirements of NFPA-33.
Instructions and safety precautions must be read
and understood prior to using this equipment.
Comply with appropriate local, state, and national
codes governing ventilation, fire protection, opera-
tion maintenance, and housekeeping. Reference
OSHA, NFPA-33, and your insurance company
requirements.
The power supply, optional remote control cabinet,
and all other electrical equipment must be located
outside Class I or II, Division 1 and 2 hazardous
areas (refer to NFPA-33).
Turn the power supply OFF before working on
the equipment.
Test only in areas free of flammable or combustible
material.
Testing may require high voltage to be on, but
only as instructed.
Production should never be done with the safety
circuits disabled.
Before turning the high voltage on, make sure no
objects are within the sparking distance.
Test Stations - Safety
4