SMS Alarm: enable SMS alarm feature
Enable Signal Quality Alarm: enable Signal Quality Alarm feature
Signal Quality Threshold: When signal alarm is generated, if realtime signal strength
is lower than Singal Quality Threshold, reset success counter to 0. If realtime signal
strength is bigger than this threshold, success counter will add one.
When signal alarm is not generated, if realtime signal strength is lower than Singal
Quality Threshold, failed counter will add one. If realtime signal strength is bigger
than this threshold, reset failed counter to 0.
Failed Times Threshold: if failed counter is more than this threshold, a signal alarm
will be generated.
Success Times Threshold: if an signal alarm is generated, and the success counter
is bigger or equal to Success Times Threshold, clear signal alarm.
Phone Number
Tel: +86-755-29230581 E-mail: sales@e-lins.com
E-Lins Technology Co.,Limited
H750 User Manual
www.e-lins.com