Figure 14: Order To Connect Flow Sensors To Ecu - Recon BLOCKAGE+ Installation Manual

Table of Contents

Advertisement

Connecting Auditory Tubes to ECUs
2. Locate the auditory tube of the sensor that is closest to the tractor when facing the back
of the tractor (labeled "1" in Figure 14) and route it toward the ECU. connect the auditory
tube to the port labeled "1". Make sure that the hose is not kinked.
Default order on left (clockwise), Reverse order on right (counterclockwise)
3. Optional: Mark the flow sensor hose with the ECU port number that the sensor is
connected to.
4. Continue connecting auditory tubes to the ECU, working clockwise around the manifold
as shown in Figure 14.
NOTE: If you connect ports in the reverse order, you can change the run direction while
configuring the system in the app.
600840-000069, rev 1.0

Figure 14: Order to connect flow sensors to ECU

Recon Blockage Plus™ Installation Manual
Page 16 of 35

Advertisement