Echo Canceller; Option Selections, Codec Timing - General DataComm TMS-3000 Operating And Installation Instructions

Celp voice channel module
Hide thumbs Also See for TMS-3000:
Table of Contents

Advertisement

Echo Canceller

TABLE 2-11. OPTION SELECTIONS, CODEC TIMING
Feature
Selection
CODEC Timing
Basecard
Source
Not Used
The CELP Module contains an Echo Canceller. This Echo Canceller can
neutralize echo in tail circuits up to 8ms round trip delay. When the tail
circuit delay is greater than this value then an external echo canceller
must be used. Note that any echo cancellation circuitry in the tail circuit
(in the range of 0 to 8ms) e.g. in a PBX must be disabled. The CELP Echo
Canceller can not be disabled (See Table 2-11).
Switch (S)
Desig.
S2-5
Plug-in
S2-5
S2-1
S2-2
S2-3
S2-4
S2-6
S2-7
S2-8
Position
OFF
This switch controls the source of timing for the
basecards CODEC IC. The CELP Plug-in always
needs to supply timing for the CODEC.
ON
Therefore, this switch should always be in the "ON"
position when the CELP plug-in is present.
OFF
Echo Canceller is always enabled
OFF
OFF
OFF
OFF
OFF
OFF
INSTALLATION
Application
2-11

Advertisement

Table of Contents
loading

Related Products for General DataComm TMS-3000

Table of Contents