Download Print this page

Braeburn Economy Series Installer's Manual page 7

3 zone control panel
Hide thumbs Also See for Economy Series:

Advertisement

Available languages

Available languages

3.7
Heat Pump System Wiring
Connect a single or multi-stage
heat pump system to the zone panel
as shown.
Conventional thermostats must be used
with a heat pump system, however,
emergency heat will be controlled by
the panel emergency heat switch or the
optional remote emergency heat switch.
For a single-stage system, the auxiliary
heat control is not used.
• Use DIP switch 1 to select between conventional and heat pump system.
• Use DIP switch 3 for heat pump reversing valve control. Setting 0 means that the O/B terminal is
active in a cooling call. Setting B means that the O/B terminal is active in a heating call.
RH
RC
1st stage
compressor
Y1
control
Y2
1st stage
G
control
G2
aux heat /
W1
E-heat
AUX
control
W2
O/B
C
7
24 VAC
2nd stage
compressor
control
fan
2nd stage
fan
control
reversing
valve
HOT
C