Download Print this page

Kärcher WRP 1000 Classic Manual page 11

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
Replacing filter inlay
1 Nut
2 Tension lever
3 Screw of the tension lever bearing
4 Hose clip
5 Cover
6 Upper section
7 Filter inlay
8 Filtrate pipe
9 Threaded rod
10 Filament filter
11 Lower part
12 Lower console
13 Pin
 Unlock filter.
 Open the hose clamps.
 Pull the hoses off the hose fittings.
 Turn out both the screws of the tension
lever bearing.
 Lift upward the entire tension lever
along with the bearings.
 Unscrew the nuts at the upper end of
the threaded rods.
 Remove the threaded rod assembly.
 Pull out the filament filter towards the
front.
 Remove the lid of the filament filter.
 Pull out the lower part of the filament fil-
ter including filter inlay.
1 Grooved stone
 Pullout the grooved stones between the
upper part and the filter inlay and be-
tween the lower part and the filter inlay.
 Remove upper and lower part of filter
inlay.
 Remove filtrate pipe from filtrate inlay,
 Dispose of the filter inlay.
 Attach filtrate pipe at one end of the
new filter inlay.
 Tighten the filter inlay in such a way that
the filaments do not twist.
 Push the fitrate pipe in the filter inlay
and by looking at the opposite side of
the filter element push the inlay in the
direction of the filtrate pipe.
 Coat all rings with normal liquid soap
before carrying out any further installa-
tion tasks.
Note
Do not use silicon grease. Silicon in water
will hamper the cleaning and drying effect
during vehicle wash.
 Insert the upper and lower part on the
filter element.
 Align the upper and lower part in such a
way that the grooved stones can be in-
serted.
 Insert the grooved stones and clamp it
tight by slightly turning the filter inlay.
 Insert the lower part into the filament fil-
ter and push it in completely.
 Replace the filament filter lid.
 Place the filament filter on the lower
console so that both the rear pins lock
into the long-holes of the console.
 Align the lid, as shown above, and push
it in completely.
 Push in the filament filter between the
two consoles.
 Hook in the threaded rod assembly at
the lower console and insert the thread-
ed rods through the holes in the upper
console.
 Fasten the threaded rods with undelay
washers and nuts.
4
-
EN
 Tighten the nuts in such a way that the
underlay washers can be still be moved
by hand.
 Insert the hoses onto the hose fittings.
 Tighten the hose clamps (keep the 35
mm distance).
 Insert the tension lever with bearing
through the lid of the filament filter.
 Turn the tightening lever in clockwise
direction. It should be possible to turn
the tightening lever in the range shown
above without exerting any pressure.
Otherwise, dismantle the tightening le-
ver and insert it again in the correct po-
sition.
 Fasten the tension lever bearings with
screws.
 Adjust the filter pre-tension.
11