Maintenance
8.5
Disassembly / Reassembly
Preliminary operations
8.5.1
Replacing the screen (3)
582216110-Filter-EN-indA
ATTENTION
Before any intervention, it is imperative to follow the
and the
safety
Remove air cap from the spray gun and put it into solvent.
Remove suction rod from the material container and inmerse it in
a solvent filled container. Take all the appropriate precautions in
the presence of flammable solvents.
Point the spray gun towards the material container and press the
gun trigger. When the solvent flows out, point the spray gun into
a recovery container.
When the solvent flows out clear and clean, release the gun
Time required
instructions.
1 minute 50
Unscrew the nut (1) manually,
Manually remove the bowl (2),
Manually remove the screen (3),
Clean or replace the screen (3),
Replace the seal (5).
decompression procedure