Safety Considerations - ICP G9MAC Series Installation Instructions Manual

Modulating gas valve, variable speed motor 35” tall high efficiency condensing gas furnace
Table of Contents

Advertisement

Safety Considerations

WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND CARBON
MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous
operation, personal injury, death, or property damage.
Improper
installation,
adjustment,
maintenance, or use can cause carbon monoxide poisoning,
explosion, fire, electrical shock, or other conditions which
may cause personal injury or property damage. Consult a
qualified service agency, local gas supplier, or your distributor
or branch for information or assistance. The qualified service
agency must use only factory−authorized and listed kits or
accessories when modifying this product.
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal injury,
death, or property damage.
Solvent cements and primers are combustible. Keep away
from heat, sparks and open flame. Use only in well−ventilated
areas. Avoid breathing in vapor or allowing contact with skin
or eyes.
CAUTION
!
FURNACE RELIABILITY HAZARD
Failure to follow this caution may result in unit component
damage.
Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature rise, unit leveling, and unit sizing.
Improper
installation,
adjustment,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions which may cause death, personal injury or
property damage. Consult a qualified installer, service agency,
local gas supplier, or your distributor or branch for information
or assistance. The qualified installer or agency must use only
factory−authorized kits or accessories when modifying this
product. Refer to the individual instructions packaged with the
kits or accessories when installing.
Installing and servicing heating equipment can be hazardous
due to gas and electrical components. Only trained and
qualified personnel should install, repair, or service
heating equipment. Untrained personnel can perform basic
maintenance functions such as cleaning and replacing air
filters. All other operations must be performed by trained
service personnel. When working on heating equipment,
observe precautions in literature, on tags, and on labels
attached to or shipped with furnace and other safety
precautions that may apply.
These instructions cover minimum requirements and conform
to existing national standards and safety codes. In some
instances, these instructions exceed certain local codes and
ordinances, especially those that may not have kept up with
changing residential construction practices. We require these
instructions as a minimum for a safe installation.
Follow all safety codes. Wear safety glasses, protective
clothing, and work gloves. Have a fire extinguisher available.
440 01 4201 03
Read these instructions thoroughly and follow all warnings or
cautions included in literature and attached to the unit.
alteration,
service,
This is the safety−alert symbol
on the furnace and in instructions or manuals, be alert to the
potential for personal injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety−alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a
hazard which could result in personal injury or death.
CAUTION is used to identify hazards which may result in minor
personal injury or product and property damage. NOTE and
NOTICE are used to highlight suggestions which will result in
enhanced installation, reliability, or operation.
alteration,
service,
Specifications subject to change without notice.
CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care
and wear appropriate protective clothing, safety glasses and
gloves when handling parts, and servicing furnaces.
1.
Use only with type of gas approved for this furnace.
Refer to the furnace rating plate.
2.
Install this furnace only in a location and position as
specified in the "Location" section of these instructions.
3.
Provide adequate combustion and ventilation air to the
furnace space as specified in "Air for Combustion and
Ventilation" section.
4.
Combustion products must be discharged outdoors.
Connect this furnace to an approved vent system only,
as specified in the "Venting" section of these
instructions.
5.
Never test for gas leaks with an open flame. Use a
commercially available soap solution made specifically
for the detection of leaks to check all connections, as
specified in the "Gas Piping" section.
6.
Always install furnace to operate within the furnace's
intended temperature−rise range with a duct system
which has an external static pressure within the
allowable range, as specified in the "Start−Up,
Adjustments, and Safety Check" section. See furnace
rating plate.
7.
When a furnace is installed so that supply ducts carry air
circulated by the furnace to areas outside the space
containing the furnace, the return air shall also be
handled by duct(s) sealed to the furnace casing and
terminating outside the space containing the furnace.
See "Air Ducts" section.
8.
A gas−fired furnace for installation in a residential
garage must be installed as specified in the warning box
in the "Location" section. (See Figure 4)
9.
The furnace may be used for construction heat provided
that the furnace installation and operation complies with
the first CAUTION in the LOCATION section on page 7
of these instructions.
10.
These Multipoise Gas−Fired Furnaces are CSA
design−certified for use with natural and propane gases
(see furnace rating plate) and for installation in alcoves,
attics, basements, closets, utility rooms, crawlspaces,
and garages. The furnace is factory−shipped for use
with natural gas. A CSA (A.G.A. and C.G.A.) listed
accessory gas conversion kit is required to convert
furnace for use with propane gas.
11.
See Table 1 for required clearances to combustible
construction.
12.
Maintain a 1−in. (25 mm) clearance from combustible
materials to supply air ductwork for a distance of 36−in.
. When you see this symbol
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

G9macF9macG9mac0802120a

Table of Contents