Voltage Trigger for X10 Type Module
4-pin header serves as voltage trigger for an optional X10 type module (PF284 or equivalent).
Keyed connector with flying leads is supplied for connection from header to X10 type module.
Requires use of relay module (4204 or 4229), which must be programmed appropriately, as
indicated in the instructions.
Memory of Alarm Voltage Trigger
A 3-pin header serves as a voltage trigger for connection to an optional strobe light, etc. Will
remain activated following any alarm that activates the external sounder, until the system is
disarmed.
Chime/Chime by Zone
Chime, when on, will normally sound when any entry/exit or perimeter zone is faulted.
However, a Òchime by zoneÓ option, when programmed, allows only specific zones to chime if
they are faulted when the system is in the chime mode.
Quick Chime Feature
The [#] key can be used in place of the security code when turning Chime on and off.
Optional Bell Supervision
Red jumper on control board, when cut, will provide supervision of bell wiring (when bell is
wired with EOL resistor, as indicated in the instructions).
Auxiliary Power Output
¥ Provides 12VDC, 500mA maximum. Uses current limiting circuitry for protection.
¥ This output interrupts for smoke detector reset if 4-wire smoke detectors are used on basic
wired zones 1Ð6 (if programmed for fire).
¥ The system can be uploaded, downloaded, or controlled via an IBM compatible computer,
Windows downloading software and a HAYES modem specified by First Alert.
Keypad programming consists of:
¥ Data field programming
¥ Interactive (menu) mode programming
For programming from a keypad, an FA550KP 2-line Alpha keypad must be connected (but need
not necessarily stay in the system).
Communication Formats Supported
¥ 4+2 Ademco Low Speed (Standard).
¥ 4+2 Radionics (Standard).
¥ 4+2 Ademco Express.
¥ Ademco Contact ID.
Zone Descriptors
You can assign Alpha descriptors to all zones (useful only when using Alpha keypads and/or
the FA4285 Phone Module).
AC Power Supply
Uses 1317 120VAC plug-in transformer with 16.5VAC 25VA output.
Back-Up Battery
Rechargeable (Gel type) 12VDC, 4AH minimum.
Section 1. General Description
1Ð3